Parameter List

3.1 Parameter List
3.1.1
Parameter list
In the initial setting, only the simple mode parameters are displayed.
Set Pr. 160 User group read selection as required.
Parameter
Name
User group read
160
selection
REMARKS
⋅ The parameters marked
⋅ The parameters marked with
value) is set in Pr. 77 Parameter write selection.
⋅ Parameters for the option are displayed only when the option unit is installed.
⋅ The instruction codes (hexadecimal) for "read" and "write" on the right of the parameter number are those used to set the
parameter via communication. "Extended" indicates the setting of the extended link parameter. (Refer to page 162 for
communication)
Instruction
Code
Function Parameters
Read
Write
00
0
Torque boost
0
80
01
1
Maximum frequency
0
81
02
2
Minimum frequency
0
82
03
3
Base frequency
0
83
Multi-speed setting (high
04
4
0
speed)
84
Multi-speed setting (middle
05
5
0
speed)
85
Multi-speed setting (low
06
6
0
speed)
86
07
7
Acceleration time
0
87
08
8
Deceleration time
0
88
09
9
Electronic thermal O/L relay
0
89
DC injection brake operation
0A
10
0
frequency
8A
DC injection brake operation
0B
11
0
time
8B
DC injection brake operation
0C
12
0
voltage
8C
0D
13
Starting frequency
0
8D
0E
14
Load pattern selection
0
8E
0F
15
Jog frequency
0
8F
Jog acceleration/deceleration
10
16
0
time
90
11
17
MRS input selection
0
91
42
Initial
Setting
Value
Range
9999
9999
are the simple mode parameters.
in the table allow its setting to be changed during operation even if "0" (initial
Name
Only the simple mode parameters can be displayed.
Simple mode and extended mode parameters can be
0
displayed.
Only the parameters registered in the user group can be
1
displayed.
Minimum
Setting Range
Setting
Increments
0 to 30%
0.1%
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 3600/ 360s
0.1/0.01s
0 to 3600/ 360s
0.1/0.01s
0 to 500/0 to 3600A
0.01/0.1A
0 to 120Hz, 9999
0.01Hz
0 to 10s, 8888
0.1s
0 to 30%
0.1%
0 to 60Hz
0.01Hz
0, 1
1
0 to 400Hz
0.01Hz
0 to 3600/360s
0.1/0.01s
0, 2
1
Remarks
Refer
Initial
Customer
to
Value
Setting
Page
6/4/3/2/
57
1.5/1%
120/60Hz
66
0Hz
66
50Hz
68
50Hz
72
30Hz
72
10Hz
72
5s/15s
79
10s/30s
79
Rated inverter
83
output current
3Hz
86
0.5s
86
4/2/1%
86
0.5Hz
81
1
70
5Hz
74
0.5s
74
0