Cbam295 Cable; Usage; Mechanical Dimension; Tightness - ETAS BR-XETK-S1.0 User Manual

Emulator probe for infineon aurix mcu family
Table of Contents

Advertisement

57 | Cables and Accessories
7.6

CBAM295 Cable

Fig. 7-12
7.6.1

Usage

BR_XETK ECU adapter and power supply cable for 100 Mbit/s Automotive Ethernet
and BR_XETKs with external power supply. Usable for ECUs without permanent
power supply inside.
7.6.2

Mechanical Dimension

Fig. 7-13
Product
CBAM295.1-0m6
CBAM295.1-1m8
7.6.3

Tightness

Condition
M12 screwing
CON1, CON4 (plugged)
7.6.4

Mounting

The CBAM295.1 cable is passed through a pre-assembled M12 screw connection.
The shield is connected to the screw. For thin walled housings, use a through bor-
ing with 12.2 mm in the housing and mount the cable with a nut. Cable delivery not
includes the nut. The nut must be ordered separately by AGRO (AGRO order num-
ber 8000.12). For wall thickness more than 2.5 mm cut a thread into the housing.
The minimum bending radius for the cable is 20 mm.
ETAS BR_XETK-S1.0 | User Guide

CBAM295 Cable

CBAM295 Dimension
Length (see Fig. 7-13)
A [mm]
400
1500
B [mm]
160
250
Degree of Protection
IP67
IP65

Advertisement