Installation; Connection To The Ecu - ETAS BR-XETK-S1.0 User Manual

Emulator probe for infineon aurix mcu family
Table of Contents

Advertisement

26 | Installation

4
Installation
This chapter contains information about the following topics:

• Connection to the ECU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

• Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
• Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Some components of the interface board may be damaged or destroyed by
electrostatic discharges. Please keep the board in its storage package until it is
installed.
The board should only be taken from its package, configured, and installed at a
work place that is protected against static discharge.
4.1
Connection to the ECU
Risk of short circuiting the internal signals of the XETK!
When you mount the XETK to the ECU, you must ensure that the screws and
washers used will not penetrate the XETK printed circuit board.
For connecting the BR_XETK-S1.0 to the ECU two XETK adapter cables are recom-
mended:
- at CON2 adapter ETAM3
- at CON4 adapter ETAM2 or ETAM5 or ETAM9 or ETAM10
The adapter cables are to be ordered separately (refer chapter "Ordering Informa-
tion" on page 73).
The suitable connectors SAMTEC-10 (CON2) and MOLEX-6 (CON4) should have
been populated onto the ECU PCB for adapters ETAM3 and ETAM2/ ETAM5/
ETAM9/ ETAM10 (see Fig. 4-2 for additional connector details).
ETAS BR_XETK-S1.0 | User Guide