00031
00032
00033
00034
Print content
7.3
1. When the communication mode is set to print, connect the printer, click the print
button on the "Statistics" interface, or send the print command through the communication
mode, the output will be as follows:
2. When the communication mode is set to result printing, the device will actively send
data. After each check, it will actively send the content shown in the following figure
through the serial port:
The format is timestamp+weight. If there is an external printing device, the above
content will be printed. The above content is only an example. The specific printed data is
subject to the actual test results.
3、The data format of CHRE mode is as follows:
Run (when writing ON, start running, stop running when
0030
writing OFF)
Zero clear (when writing ON, zero clear)
0031
Clear alarm (Clear alarm when there is an alarm written
0032
ON)
Print (when writing ON, print out)
0033
-----------------------
DATE:
TIME:
PRODUCT CODE:
TARE WT:
UP LIM:
REF WT:
LOW LIM:
PASS CT:
PASS WT:
PASS AVR:
PASS RATE:
OVER CT:
OVER WT:
UNDER CT:
UNDER WT:
TOTAL CT:
TOTAL WT:
MIN WT:
MAX WT:
-----------------------
20140503142100 0.0346kg
上分隔横线符
打印日期
2015.10.15
打印时间
15:21
产品号
1
皮重值
0.000kg
超差值
0.030kg
目标值
8.135kg
欠差值
0.030kg
合格累计次数
1
合格累计重量
8.140kg
合格平均重量
8.140kg
合格率
100.00%
超差累计次数
0
超差累计重量
0.000kg
欠差累计次数
0
欠差累计重量
0.000kg
总累计次数
1
总累计重量
8.140kg
最小值
8.140kg
最大值
8.140kg
上分隔横线符
47
CW-100G (C01+MCGS)
Need help?
Do you have a question about the Checkweigher and is the answer not in the manual?