Set The Parameters Of The Servo Driver - General Measure Checkweigher User Manual

Hide thumbs Also See for Checkweigher:
Table of Contents

Advertisement

S
leave
status
T
a
X
blank
space
Among:
(1)STX —— Start character,(02H).
(2)status ——3 bit,In case of alarm, state 1 is "E" (45H), state 2 and state 3 are
error identifications, otherwise all three bits are spaces 20H.
(3)sign —— 1 bit. Each time there is a new sampling mean, the data mark is
added by 1, from 30H to 39H, and then back to 31H. Used for auxiliary extraction of
sampling data.
(4)limit —— 1 bit is the limit of the current sampling value. The upper limit of the
sampling value is "H" (48H). If the sampling value is qualified, it is "G" (47H). If the lower
limit of the sampling value is "L" (4CH).
Sampling results
(5)
point (2EH), if there is no decimal point, the high digit is 20H).If the weight value is 3.75, it
is 30H 30H 30H 33H 2EH 37H 35H.
(7)Unit - 2 digits, "kg (6BH 67H)" for kilogram and "g (67H 20H)" for gram.
(8)CRC - is a checksum, which means that all preceding values are added and
converted to decimal, and then the last two digits are taken and converted to ASCII code.
(9)CR - return sign (0DH).
(10)LF -- Line feed sign (0AH).

Set the parameters of the servo driver

7.4
Servo-drive parameters are set as follows:
1、
Parameter restore to factory
Under enable off condition, set F0-01=1, press ENTER to confirm, then the
parameter factory restoration has been completed, do not need to power off
again.
2、
Set parameters
a, P0-01 3, Internal speed mode
b, P7-00 1&2&3, station number (set 1 for input segment, 2 for weight detection
segment and 3 for output segment)
Leave
sign
limit
a
blank
space
—— 7-digit weight data (including 6-digit content, 1-digit decimal
leave
Sampling
a
results
blank
space
48