Modify Product Parameters; Delete Product Parameters; Calibration Scale - General Measure Checkweigher User Manual

Hide thumbs Also See for Checkweigher:
Table of Contents

Advertisement

Servo longtime
Alarm&Stop

3.5.3 Modify product parameters

On the Product list page, select the product whose parameters you want to modify
from the product list and click "Product Parameters" to enter the product parameters
interface to modify the selected product parameters (the newly added product directly
jumps to the product parameters interface).
 The standard weight refers to the weight of the product to be checked, and the upper
and lower limit is the allowable deviation value of qualified product;If it is not necessary
to calculate the packaging weight of the product, the outer packaging weight of the
product can be written into the tare weight column, and the net weight should be filled
in the standard weight column.
 The product number is automatically generated by the system;The linear speed of the
belt is calculated from the detection speed, and changes with the change of the
detection speed. It cannot be filled in (the linear speed of the belt should be consistent
with the linear speed of the front and rear end conveying mechanism).
 The compensation weight difference value is calculated by dynamic calibration. Under
normal circumstances, manual change is prohibited to prevent deviation between the
product weight and the actual weight.
 When filling in the product parameters, attention should be paid to its value range.
Generally, if it is lower than the lower limit of the parameter range, the parameter
value will remain unchanged; if it is higher than the upper limit of the parameter range,
the upper limit of the parameter range will be written by default.
 The definition of weight checking speed, belt speed and correction coefficient is
described in detail on the help interface of product parameters. If necessary, you can
click "Help" to view.

3.5.4 Delete product parameters

On the product list page, select the product to be deleted and click "Delete Product"
to delete the product. After deleting the product, the following product parameters will
move forward in order, and the product number will move forward. The product cannot be
deleted during the operation of the weight check scale; In order to prevent product
parameters from being incorrectly deleted, the product name should be set reasonably
when setting product parameters.

Calibration scale

3.6
In order to ensure the correct weight of the checkweigher and the linearity of the
weight change, each checkweigher needs to carry out weight calibration and dynamic
calibration. For specific operation methods, please refer to "Operation Instructions on
Buttons and Operation Frames" in section 3.3.2.
Alarm shutdown not corrected in time
20
CW-100G (C01+MCGS)