General Measure Checkweigher User Manual page 37

Hide thumbs Also See for Checkweigher:
Table of Contents

Advertisement

I10
Run/stop [level]
I11
Run/stop [edge]
I12
Stop (level)
Output switching quantity:
Number Name
O00
Undefined
Out-of-tolerance
O01
indication
O02
Owe indication
O03
Run
O04
Stop
O05
Alarm
O06
Out-of-order
culling
O07
Owe culling
O08
Disqualified
culling
O09
Number of
batches
completed
O10
Qualifying
instructions
Control device operation or stop by level signal
When the device is in the stopped state, the signal input is
effective, the device starts to enter the running state;
When the signal input is effective, the device stops
running;
The signal is valid and the touch screen cannot start the
device
Function description
No function when this item is selected.
If the weight check result is out of tolerance, the output is
valid and continues until the next weight check is completed.
If the weight check result is underweight, the output is valid
and lasts until the next weight check is completed.
Run status output is valid.
The stopped state output is valid.
Output is valid when alarming.
The weight check result is out of tolerance, according to the
set out of tolerance eliminator distance delay, and then
according to the set duration output valid.
The weight check result is the undererror, according to the
set offset culler distance delay, and then according to the
set duration output valid.
The weight inspection result is out of tolerance or
undertolerance, according to the set distance delay of the
unqualified eliminator, and then according to the set
duration output effective.
This output is valid when the set number of batches is
reached.
If the weight check result is underweight, the output is valid
and continues until the next weight check is completed.