K1: defined as operation. When the system is in operation state, the relay output is
closed, and K1A and K1B are switched on. Used to control the start and stop of frequency
converter.
K2: defined as stop. When the system is in the stopped state, the relay output closes
and K2A and K2B are switched on. This definition is the factory default setting and can be
modified according to the actual needs.
K3: defined as out of tolerance elimination, the product test result is out of tolerance,
and within the range of out of tolerance elimination duration, the relay output is closed, K3A,
K3B switched on. This definition is the factory default setting, and can be modified
according to the actual demand.
K4: defined as under error elimination, product detection result is under error, and
within the range of under error elimination duration, the relay output is closed, K4A, K4B on.
This definition is the default setting of the factory, and can be modified according to the
actual demand.
K5: defined as alarm. When alarm occurs in the system, the output of the relay is
closed and K5A and K5B are switched on. This definition is the factory default setting, and
can be modified according to the actual demand.
K6: defined as batch completion, after the completion of the product test batch, the
relay output is closed, K6A, K6B on. This definition is the factory default setting, and can be
modified according to the actual demand.
K7: defined as qualified indication, after the product test is qualified, the relay output is
closed, K7A, K7B on. This definition is the factory default setting, and can be modified
according to the actual demand.
K8: defined as rejection of unqualified. When unqualified is detected, the output of the
relay is closed, and K8A and K8B are switched on. This definition is the factory default
setting, and can be modified according to the actual demand.