List of definable switching quantities:
Enter switch quantity:
Number Name
I00
Undefined
I01
Input
photoelectric
I02
Output
photoelectric
I03
Run
I04
Stop
I05
Clear alarm
I06
Aberration cull
complete
I07
Owe culling
complete
I08
Packet detection
I09
Belt speed
detection
DO 3
DO 4
L 1
L 2
L 3
L 4
Function description
No function when this item is selected.
When the input is valid, it means that the input
photoelectric sensor has sensed the measured object
When the input is valid, it means that the output
photoelectric sensor has sensed the object under test
When the input is valid, the device will boot into the
running state
The device will stop running when the input is valid
When the input is valid, the device will clear the current
alarm
When the input is valid, the offset cull is complete
When the input is valid, the underbalance culling has been
completed
When the input is valid, the device performs packet
connection detection
30
CW-100G (C01+MCGS)
Undefined
Undefined
O17 (Buzzer alarm output)
O7 (alarm light out-of-tolerance
indication, no relay)
O10 (alarm light qualified
indication, no relay)
O6 (alarm light undererror
indication, no relay)
Need help?