Zero tracking range
Clear range
Automatic zeroing at
startup
Check the maximum
judgment time of the
scale
Decimal point
Maximum range
Check scale for
stability time
Stabilizing time
Zero tracking time
The system
automatically clears
zeros after power-on
Feed to shake time
Time to remove
shaking from material
Length of scale table
Weight value within this range, automatically clear zero
The range at which the scale table is zeroed out during
weighing
Perform zero clearing once the scale platform is started
Is the longest judgment time in the process of weight
calibration, indicating that the weighing platform must be
stable and the zero voltage must be within the limited range
during the calibration of the empty weighing platform and the
weight calibration process. If the above conditions are not met
and the maximum judgment time is exceeded, the alarm will
be given and the weighing will fail
0 0.0 0.00 0.000 0.0000 Optional
100G
When checking the scale, the range of weight variation is
judged to be stable within the stability range of the scale
Within this setting, the range of weight variation is judged to
be stable within the range of stability
During this time, the system data drift does not exceed the
zero tracking range
Zero clearing operation will be performed once on the scale
platform
Do not sample during this time after feeding
Do not sample during this time before discharging
800mm
36
CW-100G (C01+MCGS)