● Click the "Configuration" button:
● Set the following:
4.6.1.3

Configuring safety functions

● Click the "Configuration" button.
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
– ② ③ F-DI input filter (debounce time) and monitoring for simultaneous operation
(discrepancy):
A functional description of the two filters is provided in the section F-DI signal filtering
(Page 77).
– ④ Acknowledging safety faults:
Choose a free F-DI to acknowledge the safety faults. If there are no free F-DIs
available, you have to acknowledge the safety function faults using a different method
(see Acknowledging with a fail-safe signal or with a power on reset (Page 191)).