2.8.6

Selecting SS1 when SLS is active

If you select the safety function SS1 when SLS is already active, the inverter brakes the
motor with the OFF3 ramp-down time and monitors the braking operation. When the
standstill monitoring threshold is reached, the inverter safely switches off the motor torque.
Figure 2-34
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
Selecting safety function SS1 (as an example SS1 in mode 1) when SLS is active
2.8 Interaction of the safety functions
Description
61