3.7 Forced stop deceleration function
3.7.1 Forced stop deceleration function (SS1)
When EM2 is turned off, dynamic brake will start to stop the servo motor after forced stop deceleration.
During this sequence, the display shows [AL. E6 Servo forced stop warning].
During normal operation, do not use EM2 (Forced stop 2) to alternate stop and run. The the servo amplifier
life may be shortened.

(1) Connection diagram

POINT
When alarms not related to the forced stop function occur, control of motor
deceleration can not be guaranteed. (Refer to chapter 8.)
In the torque control mode, the forced stop deceleration function is not available.
(Note)
( )
Forced
2
stop 2
Note. This diagram is for sink I/O interface. For source I/O interface, refer to section 3.9.3.
Servo amplifier
24 V DC
DC24V
DICOM
EM2