5. PARAMETERS
Setting
No./symbol/name
digit
PC05
SC1
Internal speed
command
1/internal speed
limit 1
PC06
SC2
Internal speed
command
2/internal speed
limit 2
PC07
SC3
Internal speed
command
3/internal speed
limit 3
PC08
SC4
Internal speed
command
4/internal speed
limit 4
PC09
SC5
Internal speed
command
5/internal speed
limit 5
PC10
SC6
Internal speed
command
6/internal speed
limit 6
PC11
SC7
Internal speed
command
7/internal speed
limit 7
PC12
VCM
Analog speed
command -
Maximum
speed/Analog
speed limit -
Maximum
speed
This is used to set speed 1 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 1 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 2 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 2 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 3 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 3 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 4 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 4 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 5 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 5 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 6 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 6 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 7 of internal speed commands.
Setting range: 0 to permissible instantaneous speed
This is used to set speed 7 of internal speed limits.
Setting range: 0 to permissible instantaneous speed
This is used to set the speed at the maximum input voltage (10 V) of VC (Analog
speed command).
When "0" is set, the analog speed command maximum speed would be the rated
speed of the servo motor connected.
The following shows the speed for motorless operation of test operation.
Setting range: 0 to 50000
This is used to set the speed at the maximum input voltage (10 V) of VLA (Analog
speed limit).
When "0" is set, the analog speed command maximum speed would be the rated
speed of the servo motor connected.
Setting range: 0 to 50000
Function
5 - 30
Initial
Control
value
mode
[unit]
P
S
T
100
[r/min]
500
[r/min]
1000
[r/min]
200
[r/min]
300
[r/min]
500
[r/min]
800
[r/min]
0
[r/min]