8. TROUBLESHOOTING
No.
Name
Servo amplifier overheat
warning
91
(Note 1)
Battery cable
92
disconnection warning
95
STO warning
Home position setting
96
warning
99
Stroke limit warning
9F
Battery warning
Excessive regeneration
E0
warning (Note 1)
E1
Overload warning (Note 1)
Absolute position counter
E3
warning
E5
ABS time-out warning
E6
Servo forced stop warning
Cooling fan speed
E8
reduction warning
E9
Main circuit off warning
EA
ABS servo-on warning
Overload warning 2 (Note
EC
1)
Output watt excess
ED
warning
F0
Tough drive warning
Drive recorder - Miswriting
F2
warning
Oscillation detection
F3
warning
Note 1.
Leave for about 30 minutes of cooling time after removing the cause of occurrence.
2.
Stop method indicates as follows:
DB: Stops with dynamic brake. (Coasts for the servo amplifier without dynamic brake.)
SD: Forced stop deceleration
3.
This is applicable when [Pr. PA04] is set to the initial value. The stop system of SD can be changed to DB using [Pr. PA04].
4.
Quick stop or slow stop can be selected using [Pr. PD30].
Table 8.2 Warning list
Detail
display
91.1
Main circuit device overheat warning
92.1
Encoder battery cable disconnection warning
92.3
Battery degradation
95.1
STO1 off detection
95.2
STO2 off detection
96.1
In-position warning at home positioning
96.2
Command input warning at home positioning
96.3
Servo off warning at home positioning
99.1
Forward rotation stroke limit off
99.2
Reverse rotation stroke limit off
9F.1
Low battery
E0.1
Excessive regeneration warning
E1.1
Thermal overload warning 1 during operation
E1.2
Thermal overload warning 2 during operation
E1.3
Thermal overload warning 3 during operation
E1.4
Thermal overload warning 4 during operation
E1.5
Thermal overload error 1 during a stop
E1.6
Thermal overload error 2 during a stop
E1.7
Thermal overload error 3 during a stop
E1.8
Thermal overload error 4 during a stop
Multi-revolution counter travel distance excess
E3.1
warning
E3.2
Encoder absolute positioning counter warning
E3.5
Absolute position counter warning
E5.1
Time-out during ABS data transfer
E5.2
ABSM off during ABS data transfer
E5.3
SON off during ABS data transfer
E6.1
Forced stop warning
E8.1
Decreased cooling fan speed warning
E9.1
Servo-on signal on during main circuit off
E9.2
Bus voltage drop during low speed operation
EA.1
ABS servo-on warning
EC.1
Overload warning 2
ED.1
Output watt excess warning
F0.1
Instantaneous power failure tough drive warning
F0.3
Vibration tough drive warning
F2.1
Drive recorder - Area writing time-out warning
F2.2
Drive recoder - Data miswriting warning
F3.1
Oscillation detection warning
Detail name
8 - 5
Stop method
(Note 2, 3)
DB
DB
(Note 4)
(Note 4)
SD
DB
DB