24 Chapter 1 Installing the Contivity 1740 chassis
Installing the chassis in an equipment rack
To mount the Contivity 1740 in an equipment rack, you need the following
equipment:
•
Standard 19-inch equipment rack
•
4 screws (supplied with the chassis)
•
4 cage nuts (supplied with the chassis) if the rack does not have threaded rail
holes
•
#2 Phillips screwdriver
Rack-mount recommendations
When you mount the chassis in the rack, observe the following standard
recommendations:
•
The maximum recommended ambient temperature is 40
sure that the internal temperature of the rack does not exceed 40
•
Do not block the power supply vents or otherwise restrict air flow when
installing the chassis in a rack.
•
Stabilize your rack so that it does not tip over under the weight of the gateway
and other devices.
•
Make sure that the electrical branch circuits can handle the Contivity 1740
and other units in the rack before you install and turn on the gateway.
•
Maintain a reliable earth-ground path in the rack system. The gateway is
intended to connect to an earth ground.
Attaching the shelf in the equipment rack
The Contivity 1740 ships with a rack-mount shelf to support the chassis in the
equipment rack.
To attach the shelf to the inside of the equipment rack:
1
If the holes in the rack's vertical supports are not threaded, attach a cage nut in
four locations at the front of the rack
317086-B Rev 00
o
C (104
(Figure
3).
o
F). Make
o
C (104
o
F).