5-Program 16-Segment Controller Operation - Thermo Scientific STF55433 Installation And Operating Manual

Lindberg/blue m 1500c general-purpose tube furnaces
Table of Contents

Advertisement

No.
Parameter
1
P.STAT
2
T.REMN
3
T.ELAP
4
A1.DHI
5
A2.HI
6
SP.SEL
7
SP1
8
SP2
9
RAMPU
10
SP.RAT
11
A.TUNE
12
UNITS
13
PROG
14
END.T
15
H.BACK
16
DWEL.U
17
18
TSP.1 to TSP.8
19
RMP.1 to
RMP.8
20
DWEL.1 to
DWEL.8
1500°C Tube Furnace

5-Program 16-Segment Controller Operation

The 3216p temperature process controller is a single loop PID based controller that can
store up to 5 programs with 16 segments each. This controller consists of microprocessor
based three-mode PID (Proportional, Integral, and Derivative), programmable temperature
controller and appropriate output switching devices to control the furnace. The
programmable controller can be used as a single set point controller or as a
programmable controller. The controller is capable of varying temperature or process
value with time through programming. A program is stored as a series of segments and
can be run once, repeat a set number of times or run continuously. This 16 segment
digital model can enable 16 segments in each program.
Some of the commonly used parameters in operator Level 1 and Level 2 of 3216p
controller are:
Table 2 Parameter Description and Accessibility in 3216p
Description
Program Status
Timer Remaining
Elapsed Time
Deviation High Alarm
Set Point
High Temperature
Alarm Set Point
Set point Select
Set point 1
Set point 2
Set point Ramp Units
Set point Rate Limit
Auto Tune Enable
Display Units
Current Program Num-
ber
Program End Type
Program Holdback
Dwell Units
Target Set point 1 to
Target Set point 8
Ramp Rate 1 to Ramp
Rate 8
Dwell Time 1 to Dwell
Time 8
Main Controller: 5x16 Segment Programmable |
Level
Access
Level 1 + 2
Read/Write
Level 1 + 2*
Read Only*
Level 1 + 2*
Read Only*
Level 1
Read/Write
Level 2
Read Only
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1 + 2
Read/Write
Level 1
Read Only
Level 2
Read/Write
Level 2
Read/Write
Level 2
Read/Write
Level 2
Read/Write
Chapter 6
Page
Value
no.
Reset
6-45
-
6-35
-
6-35
50
6-31
1525
6-31
SP1
6-23
25
6-24
25
6-23
Mins
6-24
Off
6-25
Off
6-26
Deg C
6-25
1 to 5
6-35
Dwell
6-43
1
6-42
6-44
Mins
6-44
550
6-44
OFF
6-44
1 hour
6-45
305435H03 | 6-39