Configuration
January 2023
4.1.4 
Scroll delay
The Scroll Delay is the time interval for the selected display items to be shown on
the Local Display. The default scroll delay setting is five seconds. Click the spin box
up or down arrow to increase or decrease the length of time an item displays.
Procedure
1. Select Finish to write the configuration settings to the meter.
2. Save the meter configuration file, collect a Maintenance log and Waveforms
4.2 
Using AMS Device Manager to configure
the meter
This procedure assumes you have AMS Device Manager installed on the host
computer and have downloaded the latest Rosemount Liquid Ultrasonic Meter
Device Description (DD).
If not installed, click the link below to download the AMS device installation tool
kit.
www.emerson.com/en-us/support/software-downloads-drivers
4.2.1 
Installing AMS Device Description
Procedure
1. Use the link above to search for the Device Description (DD) for your
2. Use the pull-down menu and select the Brand/Manufacturer - Emerson
3. Next select the Device, Liquid 3810 Series from the pull-down menu.
4. Choose the Device Revision1, from the pull-down menu.
5. Next, select HART from the Communication Protocol menu.
6. Select AMS Device Manager for the Host System.
7. Select the Host System Revision 11.5.
8. Verify your search parameters are correct, as shown below.
74
to document the "As Left" settings.
Rosemount 3810 Series Liquid Ultrasonic Flow Meter.