2.6 C
ONFIGURATION
For example, when using Table 7.3.2.(a)
Settings, if the dialer sends in a Code 06, the SYSTEM 3505 will process an Alarm for
Zone 06. If the dialer sends a code 26, Zone 06 is Secure. A code 65 indicates a
Trouble condition on Zone 15, a Code 74 indicates that Zone 15 is Secure. With Table
7.3.2.(d) Configuration #2 English Equivalent Factory Default Settings, if the dialer sends
the code E9, the SYSTEM 3505 will respond to the Daily Test.
When the dialer sends an alarm code to the SYSTEM 3505, the system looks for the
code first in the English Equivalent table and then in the Zone Setting table. Codes
MUST NOT be duplicated within Configurations. The SYSTEM 3505 only reads the first
occurrence of the code. For example, a code 30 is used to indicate Daily Test in the
English Equivalent table and then it is reused to indicate an alarm in zone 08 in the Zone
setting table. If the dialer sends an alarm code 30 for zone 8, the SYSTEM 3505 would
read it as a Daily Test. The alarm condition would never be read because the SYSTEM
3505 found the first occurrence of a code 30 in the English Equivalent table.
2.7 D
L
ATA
OSS
Some dialers provide a data loss feature. If the dialer was not successful in an attempt
to call in, it will give up. The next time it successfully makes a connection will result in a
'Data Loss' message on the SYSTEM 3505. The following message will print:
After processing a data loss, this incoming signal will produce a Daily Test message as
well. When all data is entered, press CLEAR to return to the Set Up Mode screen. At
the Set up Mode screen, press FUNC to select the screen and advance to the
CUST/CONFIG screen.
2.8 M
M
S
AIN
ENU

2.8.1 Customer ADD/CHG/DEL account

Once all Configuration tables have been set up, Customer Numbers can be added to the
system. Customer numbers are three to six digit numbers that will represent the Dialer
Account number calling in to the DDI-10E.
customer number.
Enter 1 (CUST), and the display will read:
2-8
T
D
ABLE
ETAILS
THIS IS THE FIRST
CONNECTION SINCE
AN UNSUCCESSFUL
CONNECTION ATTEMPT.
ELECTIONS
Digitize, Inc.
Specifications Subject to Change Without Notice
Configuration #1 Zone Factory Default
Do NOT include Zone numbers in the