DIGITAL DIALER RECEIVER CARD
(For units with Software Revision S603STD7.bin or later)
Digitize, Inc.
158 Edison Road
Lake Hopatcong, New Jersey 07849
Tel: (201) 663-1011
Fax: (201) 663-4333
http://www.digitize-inc.com
DDI-8
INSTALLATION
AND
OPERATION MANUAL
Part Number:
700208
Revision:
C
Issue Date:
3/97

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DDI-8 and is the answer not in the manual?

Questions and answers

Summary of Contents for DIGITIZE DDI-8

  • Page 1 DDI-8 DIGITAL DIALER RECEIVER CARD INSTALLATION OPERATION MANUAL (For units with Software Revision S603STD7.bin or later) Digitize, Inc. 158 Edison Road Lake Hopatcong, New Jersey 07849 Tel: (201) 663-1011 Part Number: 700208 Revision: Fax: (201) 663-4333 Issue Date: 3/97 http://www.digitize-inc.com...
  • Page 2 Digitize, Inc. 158 Edison Road Lake Hopatacong, NJ 07849-2217 The DIGITIZE logo is a registered trademark of Digitize, Inc.
  • Page 3 (201) 663-1011 FAX: (201) 663-4333 This manual has been prepared by DIGITIZE, INC. for use by its licensees, distributors and customers. The information contained herein is the property of DIGITIZE, INC. and may not be copied, disclosed or reproduced, in whole or in part, without the prior written approval of DIGITIZE, INC.
  • Page 4 FCC NOTICE In compliance with Paragraph 15.105 of the FCC Rules and Regulations, the following notice is provided. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5: Table Of Contents

    Table of Contents SECTION 1 OVERVIEW ......................1 - 1 SECTION 2 DDI-8 SWITCH SETTINGS .................. 2 - 1 SECTION 3 DIALER SET UP ..................... 3 - 1 3.1. PASSWORD ..........................3 - 1 3.2. CUST/CONFIG SCREEN ......................3 - 2 3.2.1. CONFIGURATION TABLES..................3 - 2 3.2.1.1.
  • Page 7: Section 1 Overview

    SYSTEM 3000. The DDI-8 is a plug-in PC card that is added to the SYSTEM 3000 card rack. The dialer option must be installed in the SYSTEM 3000 before any DDI-8 cards can be installed in the unit. The SYSTEM 3000 has up to eight card slots available for various options, including the DDI-8.
  • Page 8 The DDI-8 card processes dialer Alarm, Trouble and Restore conditions. The SYSTEM 3000 displays and prints the incoming DDI-8 signals. The user can specify Restoral = Yes or No for each account number. After an alarm or trouble condition appears, the CLEAR button will blink if an invalid account number comes through or if Restoral = N for that account number.
  • Page 9 31. Do not use zero! For example, to designate the DDI-8 board as No. 12, turn both SW3 and SW4 to OFF. SW3 = 4 and SW4 = 8. SW3 (4) + SW4 (8) = Board Number (12). Do not duplicate board numbers! Each card should be assigned a different number.
  • Page 11: Section 3 Dialer Set Up

    SECTION 3 DIALER SET UP After the DDI-8 is installed into the unit, operator will access the Set Up Mode through the front panel keypad. By pressing the SET button, the operator may step through all available menus. If pressed for over one second, the SET button will auto repeat. Direct access to the DDI-8 menu is possible by entering the menu number (16) and pressing the SET button.
  • Page 12: Cust/Config Screen

    DDI-8 INSTALLATION AND OPERATION MANUAL 3.2. CUST/CONFIG SCREEN After the password has been entered and the SET button has been pressed, the CUST/CONFIG screen will appear and the display will read: DDI - 7/8 1=CUST 2=CONFIG 3=COPY 4=ANS. PHONE HOW <<1=Set up Cust #...
  • Page 13: Translate Alarm Codes To Zones

    DDI-8 INSTALLATION AND OPERATION MANUAL 3.2.1.1. TRANSLATE ALARM CODES TO ZONES To change the default settings on Configuration 1 or 2 or to set up new Configuration Tables, Enter 1 (ZONE) and the display will read: CONFIG # 1 ZONE ¦ ALM ¦ TRB ¦ SEC 01 ¦...
  • Page 14: Set English Equivalents

    DDI-8 INSTALLATION AND OPERATION MANUAL In addition, during initialization the SYSTEM 3000 will print an error message if it discovers duplicate zones. Refer to Section 6.2 System Initialization Error Messages. When all zone data is entered, press CLEAR to return to the Set Up Mode screen. At this time the English Equivalents should be set.
  • Page 15 DDI-8 INSTALLATION AND OPERATION MANUAL Table 7.3.2.(a)- Configuration # 1 Table 7.3.2.(b) - Configuration #1 Zone Factory Default Settings English Equivalent Factory Default Settings ZONE PROCESS DAILY TEST SECURE ALL OPENING CLOSING AC FAILURE AC NOW OK LINE 1 FAULT...
  • Page 16: Copy Configurations

    DDI-8 INSTALLATION AND OPERATION MANUAL Data Loss Some dialers provide a data loss feature. If the dialer was not successful in it’s attempt to call in, it will give up. The next time it successfully makes a connection will result in a ‘Data Loss’...
  • Page 17: Add Or Delete Customer Number

    Once all Configuration tables have been set up, you are ready to add Customer Numbers to the system. Customer numbers are three to six digit numbers that will represent the Dialer Account number calling in to the DDI-8. Do NOT include Zone numbers in the customer number.
  • Page 18 DDI-8 INSTALLATION AND OPERATION MANUAL The fourth line of the display will read “SEE PRINTOUT” and an audible Trouble buzzer will sound. To silence the buzzer the operator must press “CLEAR”. The following message will print when the first dialer is missed:...
  • Page 19: Selecting Dialer Handshake

    The revolving message will read: << Use ↑↓ keys to select DDI-8 to set up. All changes are accepted when entered. YOU MUST RESTART THE SYSTEM 3000 TO ACTIVATE CHANGES. Use FUNC to move to next field. Press CLEAR to end.
  • Page 20 Press FUNC to move to the next field (1=). The revolving message will change to: << Use ↑↓ keys to select what order the handshakes should be used when the DDI-8 answers the phone. 1 = 1st, 4 = 4th. Use FUNC to move to next field. Press CLEAR to end.
  • Page 21: Section 4 Retrofits

    SYSTEM 3000, the user must install all customer numbers. The DDI-8 may be installed in place of an existing DDI-7 on units with a CPUV or earlier. In this instance, the user simply removes the DDI-7 card, sets the switches on the DDI-8 card to the proper settings and installs the DDI-8 into the unit.
  • Page 22 DDI-8 INSTALLATION AND OPERATION MANUAL Phone Line 4 Phone Line 1 Phone Line 2 Phone Line 3 Figure 4.1- P7 Header Connections 4 - 2 DIGITIZE, INC. 700208-C...
  • Page 23 Table 7.4.2 (a). For example, to designate the DDI-8 board as No. 12, turn both SW3 and SW4 to OFF. SW3 = 4 and SW4 = 8. SW3 (4) + SW4 (8) = Board Number (12). Do not duplicate board numbers! Each card should be assigned a different number.
  • Page 24: Retrofit Switch Restrictions

    DDI-8 INSTALLATION AND OPERATION MANUAL 4.2.1. RETROFIT SWITCH RESTRICTIONS There are further restrictions that apply to units utilizing the DDI-8 in the DDI-7 alarm reporting format. These restrictions apply to pulse code transmission protocols only. 1. Only 3/1, 3/1 extended, 4/1 and 4/2 formats will be processed. Extended format is active for all four character long messages.
  • Page 25 The DDI-8 converts any single digit alarm message to a two digit message. When alarm code 123- X is sent to the dialer, the SYSTEM 3000 processes a code 123-XX (where xx is zone 01 - zone 99).
  • Page 26: Enable Mode

    Fire code requires two phone lines to the monitoring equipment. On SYSTEM 3000 units with two phone lines (two DDI-8 cards), if the first phone line is unable to make a connection, the phone automatically hunts to the second phone line (second DDI-8). (Please note: The hunt feature is provided by your local phone company, not Digitize, Inc.
  • Page 27: Section 6 Diagnostics

    DIAGNOSTICS 6.1. SYSTEM TEST The DDI-8 performs a self test when the System 3000 is powered up. To view the self test the user must remove the cover of the SYSTEM 3000. The position of SW7 determines if the DDI- 8 performs a full diagnostic test or a quick test version.
  • Page 28 DDI-8 INSTALLATION AND OPERATION MANUAL Table 7.5 -Diagnostic Self Test for DDI-8 Test Description Error Code Number EPROM U6 Checksum 1 - Checksum failure RAM U7 test 1 - Read/Write error 2 - Address or data interference U4 Timer test 1 - No response error Ref.: CPU clock (11.059 MHz)
  • Page 29: System Initialization Error Messages

    DDI-8 EPROM chip. Please note: If the customer is using a DDI-8 in a DDI-7 mode (with a CPUV), the program version will always default to one level less than the program version used on a DDI-8 with a CPUVI.
  • Page 30: Incorrect Dialer Handshake

    Refer to Section 3.2.4 Dialer Handshake for details. 6.2.4. DUPLICATE CONFIGURATION DATA After the DDI-8 is installed and the SYSTEM 3000 is restarted, the SYSTEM 3000 will check the DDI-8 configuration tables for duplicate codes. During initialization the following...
  • Page 31 Bad Send DMTF Tone Saw Soft Reset Error May indicate hardware problem (SYSTEM 3000 had to issue a reset command to DDI-8 card) OR may indicate a software bug. DD Type Array is Full Indicates program bug in SYSTEM 3000 operating system.
  • Page 33: Section 7 Fcc Information

    SECTION 7 FCC INFORMATION The DDI-8 connects to the telephone line by means of a standard jack (USOC RJ11 C or USOC RJ45 S). Connection to telephone company coin operated service (central office implemented system) is prohibited. Connection to party line service is subject to State tariffs.
  • Page 34 DDI-8 INSTALLATION AND OPERATION MANUAL Zone Settings Worksheet Configuration # ___________ ZONE ALM TRB ZONE ALM TRB ZONE ALM TRB 7- 2 DIGITIZE, INC. 700208-C...
  • Page 35 DDI-8 INSTALLATION AND OPERATION MANUAL E nglish E quivalent W orksheet C o nfig uratio n # ___ __________ __ PR O C E SS FO R D A ILY T E ST SE C UR E A LL O PE N IN G...
  • Page 37 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 or art thereof not manufactured by Digitize, only the warranty, if any, given by the manufacturer...

Table of Contents