The CHARGING indicator LED remains lit continuously during the first stage of the charge
cycle. The charge current will be displayed on the BATTERY CHARGER FACEPLATE.
To display the Battery Voltage, press (push) in and hold the BATTERY VOLTAGE button.
Do not disconnect any output leads or connectors between the batteries and the charger when the charger
is on. To stop a charge in progress, always unplug the extension cord from the AC power source.
Recharge batteries in a well-ventilated area only. Do not charge batteries near fire, spark or other potential
ignition sources. Batteries may emit highly explosive hydrogen gas while charging. Failure to properly
ventilate the charge gasses could result in death or serious injury. Always charge aerial work platform
batteries away from flammable materials.
ALWAYS avoid contact with battery acid. Battery acid causes serious burns and should be kept away from
skin or eyes. If contact occurs, flush with water and consult a physician immediately.
When there is a fault, the LED indicator flashes in various colours depending on the type of
alarm :
State of flashing
indicator
Red
Battery presence
Yellow
Temperature probe
Green
Specified time
Red-Yellow
Battery current
Red-Green
Battery voltage
Red-Yellow-Green
Temperature
In case of an alarm, the charger stops supplying power.
When the battery charge reaches 80% of capacity, the yellow 80% CHARGED indicator LED
will become lit and the green CHARGING indicator LED will begin to flash.
Unplug the extension cord from the outlet and the charger receptacle on the aerial work
platform. Store the extension cord for next use.
N.B.-:-A
PLATFORM
4001182150
Type of alarm
Battery not connected or not compliant : Check connection or rated voltage.
Temperature probe disconnected while charging or outside the functional range :
Check connection and measure battery temperature.
Phase 1 or 2 is longer than the maximum allowed time : Check battery capacity.
Loss of output current control : Faulty control logic.
Loss of output voltage control : Battery disconnected or faulty control logic.
Overheating of semiconductors : Check fan operation.
LWAYS UNPLUG THE BATTERY CHARGER POWER CORD BEFORE MOVING THE AERIAL WORK
. F
AILURE TO DISCONNECT POWER CORD COULD CAUSE DAMAGE TO THE EQUIPMENT
E 08.21
Description (Action)
USA / GB
A
B
C
D
E
F
.
G
H
I