Pump Settings; Set Date And Time; Set Time & Am/Pm Or 24 Hour Clock; Set Min/Max Speeds - Pentair INTELLIFLOXF Installation And User Manual

Variable speed pump
Hide thumbs Also See for INTELLIFLOXF:
Table of Contents

Advertisement

8
MENU
Pump Menu: Settings

Pump Address

SETTINGS

Set Date and Time

The time controls all scheduled times, functions, and
programmed cycles and stores the correct time for up to
96 hours after power is turned off. Reset if the power is
Temperature Unit
off longer than 96 hours.
1. Check that the green power LED is on.
Screen Contrast
2. Press Menu.
3. Press Select to select "Settings".
Set Min Speed
4. Use the Up or Down arrows to scroll to "Date and
Time" and press Select.
Set Max Speed
5. Press Select again and use Up or Down arrows to
set the date.
PASSWORD
6. Press Save to save user input and return to "Date
and Time."
7. Use the Up or Down arrows to scroll to "Time" and
press Select.
8. Use the Up or Down arrows to scroll to set the time.
Note: To set AM/PM or a 24 hour clock see the next
section "Set AM/PM or 24 Hour Clock."
9. Press Save to save. To cancel any changes, press
Back to exit without saving.
10. Press Back to exit.
Set AM/PM or 24 Hour Clock
To change the time from a 12 hour clock (AM/PM) to a
24 hour clock:
1. Press Menu.
2. Press Select to select "Settings".
3. Use the Up or Down arrows to scroll to "Date and
Time" and press Select.
4. Use the Up or Down arrows to scroll to "AM/PM" and
press Select.
5. Use the Up or Down arrows to scroll to choose
between 24 hr. and AM/PM.
6. Press Save to save. To cancel any changes, press
Back to exit without saving.
7. Press Back to exit.
Set Minimum Speed (RPM)
The minimum pump speed can be set from 450 RPM to
1700 RPM. The default setting is 450 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Min/Max".
5. Use the Up or Down arrows to scroll to "Set Min Spd".
6. Press Select to change the setting. The cursor will
appear in the first number column (ones).
XF
®
INTELLIFLO
and INTELLIPRO
(1-16) Default: ADDRESS 1
Set Time
(hr:mm) Default: 12:00 AM
AM/PM
Set AM/PM
24 hr.
Fahrenheit - Default: F°
C° Celsius
(1-5) Default 3
English - Default: English
Language
(450 RPM - 1700 RPM) - Default: 450 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Disabled/Enabled - Default: Disabled
Password Time Out (1 min. - 6 hours) Default:10 minutes
Enter Password (xxxx) Default: 1234
XF
®
Variable Speed Pump Installation and User' s Guide
7. Press the Up or Down arrows to change the minimum
speed setting from 450 to 1700 RPM.
8. Press Save to save. To cancel, press Back to exit edit
mode without saving.
9. Press Back to exit.
Set Maximum Speed (RPM)
The maximum speed can be set from 1900 RPM to
3450 RPM (default is 3450). Use this setting to set the
maximum running speed of the pump.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Min/Max".
5. Use the Up or Down arrows to scroll to "Set Max Spd".
6. Press Select to change. The cursor will appear in the
first number column (ones).
7. Press Up or Down arrows to change the maximum
speed setting from 1900 to 3450 RPM.
8. Press Save to save. Press Back to exit. To cancel,
press the Back to exit without saving.
Note: Maximum Speed will limit Priming Speed, except in
one case. If the Maximum Speed is set below the lowest
available Priming Speed (2350 RPM) then the pump will
exceed the Maximum Speed while the priming feature
is running. This prevents the pump from having trouble
priming if the Maximum Speed is set this low. If this is a
problem, priming can be disabled in the Priming Menu
(see Priming section on page 13).
Pump Address
The default pump address is #1 and only needs to be
changed when there is more than one pump on an
automation system. Change the address to allow the
automation system to send a command to the correct
pump.
Use this setting if your pump is connected via the RS-485
COM port to an IntelliTouch
Control System or IntelliComm
For EasyTouch, SunTouch or IntelliComm systems, the
pump only communicates with address #1. The pump
address can be set from 1-16. The IntelliTouch system
can communicate to only four (1-4) pumps.
Note: IntelliFloXF pumps cannot be connected in series
with other pumps.
1. Be sure the green power LED is on and the pump is
stopped.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Device" and
press Select.
, EasyTouch
, SunTouch
®
®
Communication Center.
®
®