MENU
Pump Menu: Settings
SETTINGS
Pump Address
Pump Address
(cont.)
5. Use the Up or Down arrows to scroll to "Pump Address"
and press Select.
Temperature Unit
6. Press Up or Down arrows to change the address
number from 1-16.
Screen Contrast
7. Press Save to save. To cancel any changes, press
Back to exit without saving.
8. Press Back to exit.
Set Min Speed

Set Screen Contrast

Set Max Speed
The default setting for the LCD screen is 3. Screen
contrast levels can be adjusted from 0 to 7 units for low
PASSWORD
or high lighting conditions.
Note: Changes to the contrast setting do not update
instantaneously. Changes to this setting must be saved
before the contrast level changes.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrow to scroll to "Device" and
press Select.
5. Use the Up or Down arrow to scroll to "Contrast
Level."
6. Press Select. Screen will show current contrast
setting number. Use Up or Down to change number.
7. Press Save to save. To cancel any changes, press
Back to exit without saving.
8. Press the Back button to exit.

Set Control Panel Language

To access the language menu:
1. Check that the green power LED is on.
2. Press Menu and press Select to select "Settings".
3. Use the Up or Down arrows and scroll to "Device" and
press Select.
4. Use the Up or Down arrows to scroll to "Select Language
and press Select.
5. Use the Up or Down arrows to choose the desired
language.
6. Press Save to select the control panel language. To
cancel any changes, press Back to exit without saving.
7. Press Back to exit.
(1-16) Default: ADDRESS 1
Set Time
(hr:mm) Default: 12:00 AM
AM/PM
Set AM/PM
24 hr.
Fahrenheit - Default: F°
C° Celsius
(1-5) Default 3
English - Default: English
Language
(450 RPM - 1700 RPM) - Default: 450 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Disabled/Enabled - Default: Disabled
Password Time Out (1 min. - 6 hours) Default:10 minutes
Enter Password (xxxx) Default: 1234
INTELLIFLO

Set Temperature Unit

The pump can be set to either Celsius (°C) or Fahrenheit
(°F). The default setting is Fahrenheit (°F).
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Device" menu
item. Press Select.
5. Use Up or Down arrows to scroll to "Temperature Units"
and press Select.
6. Use Up or Down arrows to choose Celsius (°C) or
Fahrenheit (°F).
7. Press Save to save. To cancel any changes, press Back
to exit without saving.
8. Press Back to exit.

Password Protection

The default setting for password protection is disabled.
When this feature is enabled, the pump display will
prompt for the password before allowing access to the
control panel and buttons.
The entered password is any combination of four digits.
• The pump can always be stopped by pressing Start/
Stop, even when password protection is enabled.
• Password protection cannot be turned back on with
Start/Stop while running in manual mode.
• Pressing Start/Stop when the pump is off will return it
back to the Running Cycles Mode and run at the next
scheduled run time. If the present time is within the
scheduled run time, the pump will run the scheduled
speed.
• All functions including programming are disabled in
Password Protection Mode.
• Screen will read "Enter Password" if any button other
than the Start/Stop button is pressed
• Key icon displayed in the upper left side of the screen
when Password Protection is on.
750 RPM
750 RPM
Actual Speed
Running Speed 1
XF
XF
®
®
and INTELLIPRO
Variable Speed Pump Installation and User' s Guide
Password
Protection
Enabled
12:15
9