Connecting the Pump to a SunTouch
The pump can be controlled by a SunTouch system via
the RS-485 communication cable.
To connect the pump RS-485 communication cable to
the SunTouch control system circuit board:
1. Unlatch the front door of the SunTouch system
power center and open the door.
2. Loosen the retaining screw on front panel. Open
the hinged front panel to access the electronics
compartment.
3. Route the two conductor cable up through the
power center grommet opening located on the left
side, and up through the low voltage raceway to
the motherboard.
Control System
®
J11
COM PORT
RS-485 Communication
Cable (P/N 350122)
230 VAC Power to Pump
SunTouch Control System Circuit Board
XF
INTELLIFLO
Switch OFF main system power to the SunTouch
system power center before making any connections.
4. Strip back the cable conductors 6 mm (1/4"). Insert
the wires into the screw terminals (provided).
Secure the wires with the screws. Be sure to match
the color coding of the wires;
YELLOW to YELLOW and GREEN to GREEN.
5. Insert the connector on the COMPORT (J11) screw
terminal on the SunTouch system circuit board.
6. Close the control panel and secure it with the
retaining screw.
7. Close the front door. Fasten the spring latch.
GAS
HEATER
RESET
Pump
Drive
XF
®
®
and INTELLIPRO
Variable Speed Pump Installation and User' s Guide