External Control with IntelliComm
Communication Center
Use the RS-485 communications cable to remotely
control the pump from an IntelliComm communication
center. The IntelliComm system provides four pairs
of input terminal connections. These inputs are
actuated by either 15 - 240 VAC or 15 - 100 VDC. Use
the device inputs, to control the programmed pump
speeds.
Note: For the pump to accept commands from the
IntelliComm system, the pump must be in the "Running
Schedules" mode (LED above Start/Stop button is on).
If more than one input is active, the highest number
will be communicated to the pump. The IntelliComm
system will always communicate to pump using
ADDRESS #1.
Program Number Priority
If programs 1 and 2 are activated, program 2 will run,
regardless of the assigned speed (RPM). The higher
program number will always take priority.
Refer back to page 12 for instructions for setting up
Programs in the External Control menu.
External Control is for programming speeds that will
run when the IntelliComm communication center
controller sends it a command.
For example, Terminal 3 and 4 in IntelliComm system
will correspond to External Control Program #1. (5
and 6 to Ext Ctrl #2). Use the External Control feature
to program the IntelliComm communication center.
Connecting to EasyTouch
IntelliTouch
Control Systems
®
The pump can be controlled by an EasyTouch or
IntelliTouch system via the RS-485 communication
cable. The EasyTouch and/or IntelliTouch control
system starts, stops and controls the speed of the pump.
EasyTouch and/or IntelliTouch systems rewrite the
pump memory when a command is given. This can
take several seconds and can cause a delay until the
pump physically responds.
The pump control panel is disabled when
communicating with an EasyTouch and/or IntelliTouch
system. The EasyTouch and/or IntelliTouch system
will not start communicating with the pump until
the pump is assigned to a circuit. The default pump
address is "1" (only address for EasyTouch system).

CONNECTING TO AN AUTOMATION SYSTEM

®
and
®
XF
®
INTELLIFLO
and INTELLIPRO
Wiring Terminal Descriptions for IntelliComm
Communication Center
Terminal
Terminal
Voltage
Number
Name
Power
100 - 240
1-2
Supply
VAC
15 - 240
VAC
Program
3-4
or
1
15 - 100
VDC
15 - 240
VAC
Program
5-6
or
2
15 - 100
VDC
15 - 240
VAC
Program
7-8
or
3
15 - 100
VDC
15 - 240
VAC
Program
9-10
or
4
15 - 100
VDC
RS-485
11
+ Data:
-5 to +5
12
Yellow
VDC
- Data:
Green
Ground
IntelliComm Communication Center
See page 8 for details about how to check and or set
the pump address. For more information, refer to the
IntelliTouch (P/N 520100) or EasyTouch Automation
System User's Guide (P/N 520584).
Installation and User's Guides are available at:
www.pentair.com.
XF
®
Variable Speed Pump Installation and User' s Guide
17
Max.
Phase
Frequency
Current
Type
100 mA
1 Input
50/60 Hz
1 mA
1 Input
50/60 Hz
1 mA
1 Input
50/60 Hz
1 mA
1 Input
50/60 Hz
1 mA
1 Input
50/60 Hz
1 Out-
5 mA
N/A
put