Thermal Mode - Pentair INTELLIFLOXF Installation And User Manual

Variable speed pump
Hide thumbs Also See for INTELLIFLOXF:
Table of Contents

Advertisement

16
MENU
Pump Menu: Thermal Mode

THERMAL MODE

DISABLED/ENABLED
PRIMING
DISABLED/ENABLED
MAX PRIMING TIME
The sensor for Thermal Mode is in the drive, on top of the
motor. This feature allows you to set a speed (450 RPM -
PUMP TEMPERATURE
PRIMED SENSITIVITY
3450 RPM) that runs when the pump goes into Thermal
Mode. The temperature level that you wish Thermal Mode
PRIMING DELAY
to start can also be set.
DISABLED/ENABLED
IMPORTANT NOTE: This feature is for protection of the
pump. Do not depend on the Thermal Mode feature for
freeze protection of the pool. Certain situations could
cause the pump to sense a different temperature than
actual air temperature.
Your automation systems air temperature sensor should
be used to sense actual temperature. For example, if the
pump is located indoors, the temperature of the room
does not indicate the outdoor temperature. The pump
does not sense the water temperature.
To access the Thermal Mode menu:
1. Check that the green power LED is on.
2. Press Menu.
3. Use the Down arrow to scroll to "Thermal Mode"
and press Select.
4. The factory default for Thermal Mode is "Enabled".
To disable Thermal Mode, press Select to highlight
"Enabled".
5. Press the Up arrow - "Disabled" is displayed.
6. Press Save to save.
ThermMode
1000
Set Speed
Setting the Thermal Mode Pump Speed
THERMAL MODE
XF
®
INTELLIFLO
and INTELLIPRO
Disabled / Enabled - Default: Enabled
Default: Enabled
SET SPEED
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
(1 min. to 30 min. hrs.) Default: 11 minutes
40° F - 50° F (4.4° C - 10° C) Default: 40° F (4.4° C)
(1 - 100%) Default: 1
(1 second - 10 minutes) Default: 20 seconds
Disabled / Enabled - Default: Enabled
12:15p
RPM
DISABLED/ENABLED
SET SPEED
PUMP TEMPERATURE
Thermal Mode Menu Options
XF
®
Variable Speed Pump Installation and User' s Guide
To Set Thermal Mode Speed and Pump Temperature:
Note: Thermal Mode features are only accessible if
Thermal Mode is "Enabled".
1. With "Thermal Mode" displayed on the screen,
press the Down arrow -
The factory default is 1000 RPM.
2. Press Select to change the speed. The cursor will
highlight the first column (ones).
3. Use the Up or Down arrows to set speed (450 -
3450 RPM).
4. Press Save to save the speed.
5. Press the Down arrow to Pump Temperature
This setting determines when Thermal Mode is
activated. Default setting is 40°F (4.4°C)
6. Press Select to change the setting. The cursor will
highlight the first column. Can be set
(4.4°C - 10°C).
7. Press Save to save the temperature setting.
Note: To cancel any changes, press Back to exit
without saving.
8. Press Back to exit.
ThermMode
40
Pump Temperature
Setting the Thermal Mode Pump Temperature
Disabled / Enabled - Default: Enabled
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
40° F - 50° F (4.4° C - 10° C) Default: 40° F (4.4° C)
"Set Speed" is displayed.
40°F to 50°F
12:15p
F
°

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intelliproxf

Table of Contents