Pump Settings; Set Date And Time; Set Am/Pm Or 24 Clock; Set Min/Max Speeds - Pentair IntelliFlo Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

MENU
Pump Menu: Settings
SETTINGS

Set Date and Time

The time controls all scheduled times, functions, and
programmed cycles and stores the correct time for up
to 96 hours after power is turned off. Reset if the power
Temperature Unit
is off longer than 96 hours.
1. Check that the green power LED is on.
Screen Contrast
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Date and
Time" and press Select.
5. Press Select again and use Up or Down arrows to
set the date.
6. Press Save to save user input and return to "Date
and Time."
7. Use the Up or Down arrows to scroll to "Time" and
press Select.
8. Use the Up or Down arrows to scroll to set the time.
Note: To set AM/PM or a 24 hour clock see the next
section "Set AM/PM or 24 Hour Clock."
9. Press Save to save. To cancel any changes, press
Back to exit without saving.
10. Press Back to exit.
Set AM/PM or 24 Hour Clock
To change the time from a 12 hour clock (AM/PM) to a
24 hour clock:
1. Press Menu.
2. Press Select to select "Settings".
3. Use the Up or Down arrows to scroll to "Date and
Time" and press Select.
4. Use the Up or Down arrows to scroll to "AM/PM"
and press Select.
5. Use the Up or Down arrows to scroll to choose
between 24 hr. and AM/PM.
6. Press Save to save. To cancel any changes, press
Back to exit without saving.
7. Press Back to exit.
Set Minimum Speed (RPM)
The minimum pump speed can be set from 450 RPM
to 1700 RPM. The default setting is 450 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Min/Max".
5. Use the Up or Down arrows to scroll to "Set Min Spd".
6. Press Select to change the setting. The cursor will
appear in the first number column (ones).

Pump Address

(1-16) Default: ADDRESS 1
Set Time
(hr:mm) Default: 12:00 AM
AM/PM
Set AM/PM
24 hr.
Fahrenheit - Default: F°
C° Celsius
(1-5) Default 3
English - Default: English
Language
Set Min Speed
(450 RPM - 1700 RPM) - Default: 450 RPM
Set Max Speed
(1900 RPM - 3450 RPM) - Default: 3450 RPM
PASSWORD
Disabled/Enabled - Default: Disabled
Password Time Out (1 min. - 6 hours) Default:10 minutes
Enter Password (xxxx) Default: 1234
7. Press the Up or Down arrows to change the minimum
speed setting from 450 to 1700 RPM.
8. Press Save to save. To cancel, press Back to exit
edit mode without saving.
9. Press Back to exit.
Set Maximum Speed (RPM)
The maximum speed can be set from 1900 RPM to
3450 RPM (default is 3450). Use this setting to set the
maximum running speed of the IntelliFlo
Pump.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Min/Max".
5. Use the Up or Down arrows to scroll to "Set Max Spd".
6. Press Select to change. The cursor will appear in
the first number column (ones).
7. Press Up or Down arrows to change the maximum
speed setting from 1900 to 3450 RPM.
8. Press Save to save. Press Back to exit. To cancel,
press the Back to exit without saving.
Note: Maximum Speed will limit Priming Speed,
except in one case. If the Maximum Speed is set below
the lowest available Priming Speed (2350 RPM) then
the pump will exceed the Maximum Speed while the
priming feature is running. This prevents the pump
from having trouble priming if the Maximum Speed
is set this low. If this is a problem, priming can be
disabled in the Priming Menu (see "Priming" section
on page 14).
Pump Address
Use this setting if your pump is connected via the RS-485
COM port to a Pentair automation system.
The default pump address is #1 and only needs to be
changed when there is more than one pump on an
automation system. When multiple pumps are on the
same system, you may change each pump's address to
allow the automation system to send a command to the
correct pump. The pump address can be set from 1-16.
Refer to the automation system manual for further
details on how to connect and use an automation
system with your variable speed pump.
1. Be sure the green power LED is on and the pump
is stopped.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Device"
and press Select.
5. Use the Up or Down arrows to scroll to "Pump
Address" and press Select.
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
9
®