Setting Priming Features; Disabling Priming With An Automation System - Pentair INTELLIFLOXF Installation And User Manual

Variable speed pump
Hide thumbs Also See for INTELLIFLOXF:
Table of Contents

Advertisement

MENU
Pump Menu: Priming
PRIMING
DISABLED/ENABLED
MAX PRIMING TIME

Setting Priming Features

Note: Priming features are only accessible if priming
PRIMED SENSITIVITY
is "Enabled".
PRIMING DELAY
1. Press Menu.
2. Use Down arrow to scroll to "Priming" and press
DISABLED/ENABLED
Select.
3. The factory default is set to priming "Enabled". To
disable, press Select.
4. Press Save if you have changed the setting - this
will save the selection.
5. Press the Down arrow - the screen will read "Max
Priming Time".
6. To change from factory default, press Select. The
cursor will highlight.
7. Use the Up or Down arrows to change the time
from 1 minute to 30 minutes.
8. Press Save to save.
9. Press the Down arrow - the screen will read
"Priming Range". Default is "5".
10. Press Select to change the priming range. The
cursor will highlight the number.
11. Use the Up or Down arrows to change from 1
to 10. Increasing the number allows the drive to
detect prime with less water flow.
12. Press Save to save.
13. Press the Down arrow - the screen will read
"Priming Delay". Default is 20 seconds.
14. Press Select to change the priming delay time.
15. Use the Up or Down arrows to change from 1
second to 10 minutes.
CAUTION: Increasing the time causes the pump to
stay in the priming mode longer.
1. Disable priming on automation control system.
3. Disable priming on pump.
Default: Enabled
(1 min. to 30 min. hrs.) Default: 11 minutes
16. Press Save to save the setting.
17. Press Back to exit.
(1 - 100%) Default: 1

Disabling Priming with an Automation System

(1 second - 10 minutes) Default: 20 seconds
When the pump is connected to an automation control
Disabled / Enabled - Default: Enabled
system, (IntelliTouch
Systems), the priming feature on the pump cannot be
disabled by the external automation control system
only. It must also be disabled on the pump itself.
If priming is enabled on start up, the pump responds to
its internal settings before responding to commands from
an automation control system.
If the pump is connected to an automation control
system and priming is not desired, disable the priming
feature on both the pump and the automation control
system.
To disable priming with an automation system:
1. Disable the priming feature on the automation control
system at the load center or using an IntelliTouch
or EasyTouch system remote. (Refer to the
automation control system user's guide for additional
information).
2. Temporarily disconnect the RS-485 communication
cable.
3. Open the lid to the control panel to disable priming
on the pump. Press Menu, use the Arrow buttons
to scroll and select "Priming", then select "Disabled"
(the factory default is set to "Enabled"). Press Save
to save the setting. Press Back to exit the menu.
4. Once priming is disabled, reinstall the RS-485
communication cable.
2. Disconnect the RS-485 communication cable.
4. Reinstall the RS-485 communication cable.
XF
®
INTELLIFLO
and INTELLIPRO
, EasyTouch
®
®
XF
®
Variable Speed Pump Installation and User' s Guide
15
or SunTouch
Control
®