MENU
Pump Menu: Features

FEATURES

Time Out

The Time Out feature keeps the pump from running it's
programmed speeds for a set duration adjustable in the
menu. The Time Out feature is displayed in hours and
minutes (Hrs:Mins).
Once Time Out is finished, the pump will return to its
previous mode of operation, the Start/Stop LED will be lit
and ready to turn on at the next scheduled run time.
To access the Time Out menu:
1. Check that the green power LED is on.
2. Press Menu.
3. Use Up or Down arrows to scroll to "Features",
then press Select.
4. Press Select to choose "Timeout".
5. Then press Select again to choose "Timeout
Duration".
6. Press Select to change the time. The cursor will
highlight the minutes column.
7. Press the Left arrow to move cursor to the hours
column.
Time out can be set from 1 minute to 10
hours.
8. Press Save to save the setting.
Note: To cancel any changes, press Back to exit
without saving.
9. Press Back to exit the menu.
Quick Clean
Note: Quick Clean is the only high-speed override
feature of the pump.
This feature can be used to increase the pump speed for
vacuuming, cleaning, adding chemicals, after a storm for
extra skimming capability.
Press the Quick Clean button (LED on) and then
Start/Stop to start. When the Quick Clean cycle is over,
the pump will resume regular schedules and be in
"Running Schedule" mode.
To access the Quick Clean menu:
1. Check that the green power LED is on and the
pump is stopped.
2. Press Menu.
3. Use Up or Down arrows to scroll to "Features",
then press Select.
4. Press the Down arrow and press Select for "Quick
Clean".
5. Press Select to choose "Set Speed".
6. Press Select to highlight the "RPM" first (ones)
column and change the speed.
7. Use Up or Down arrows to change the speed.
Time Out
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Set Speed (1100 -3450 RPM) Default: 3450 RPM
Quick Clean
Time (1 min. to 10 hrs.) Default: 10 minutes
INTELLIFLO
8. Press Save to save the speed.
9. Press the Down arrow again, and press Select for
"Time Duration".
10. Press Select to change the time. The cursor will
highlight the minutes column.
11. Use Up or Down arrows to change the time from 1
minute to 10 hours.
12. Press Save to save the time.
13. Press Back to exit the menu.
MENU

PRIMING

The default setting for Priming is ENABLED. This
setting allows the pump to automatically detect if it is
primed for startup.
The priming feature increases the pump speed to 1800
RPM and pauses for 3 seconds. If there is sufficient
water flow in the pump basket, the pump will go out of
priming mode and run its commanded speed.
If the water flow is not sufficient, the pump speed will
increase to the "Max Speed" setting and remain for
the priming delay time (default 20 seconds). If there is
sufficient water flow in the pump basket at this time, it
will exit priming mode and transition to the commanded
speed.
If there is still insufficient flow in the pump basket, as
determined by the Priming Range setting, the pump will
try to prime at the "Priming Speed" for the amount of time
set in the "Maximum Priming Time" menu, unless the set
"Maximum Speed" is lower than the set "Priming Speed".
Once the pump achieves prime, it will resume normal
operation after the preset priming delay.
Note: It is possible to set "Maximum Speed" too low for
the pump to properly prime. Maximum Speed will limit
Priming Speed, except in one case. If the Maximum
Speed is set below the lowest available Priming Speed
(2350 RPM) then the pump will exceed the Maximum
Speed while the priming feature is running. This
prevents the pump from having trouble priming if the
Maximum Speed is set this low. If this is a problem,
priming can be disabled in the Priming Menu.
XF
XF
®
®
and INTELLIPRO
Variable Speed Pump Installation and User' s Guide
Pump Menu: Priming
DISABLED/ENABLED
MAX PRIMING TIME
PRIMED SENSITIVITY
PRIMING DELAY
DISABLED/ENABLED
12:15p
1800 RPM
1800 RPM
T 00:01 460 WATTS
Priming
Display during priming
13
Default: Enabled
(1 min. to 30 min. hrs.)
(1 - 100%) Default: 1