Pentair STA-RITE INTELLIFLO3 VSF User Manual

Pentair STA-RITE INTELLIFLO3 VSF User Manual

Variable speed and flow pumps
Hide thumbs Also See for STA-RITE INTELLIFLO3 VSF:

Advertisement

Quick Links

PENTAIR HOME
FOR INTELLIFLO3™ VSF AND INTELLIPRO3™ VSF
VARIABLE SPEED AND FLOW PUMPS
USER'S GUIDE
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Digital copies of all IntelliFlo3 VSF manuals,
as well as translated versions, can be found
at www.pentair.com, or by scanning the
provided QR code.
• Install and Maintenance Guide (P/N 356231)
• User's Guide (P/N 356088)
Se pueden encontrar copias digitales de
todos los manuales de IntelliFlo3 VSF,
así como versiones traducidas en www.
pentair.com, o escaneando el código QR
proporcionado.
• Guía de instalación y servicio (P/N 357973)
• Guía del usuario (P/N 357971)
Des copies numériques de tous les manuels
IntellFlo3 VSF, ainsi que les versions traduites,
peuvent être trouvées sur www.pentair.com, ou
en scannant le code QR fourni.
• Guide d'installation et d'entretien (P/N 357974)
• Guide d'utilisation (P/N 357972)

Advertisement

Table of Contents
loading

Summary of Contents for Pentair STA-RITE INTELLIFLO3 VSF

  • Page 1 IntelliFlo3 VSF, IntellFlo3 VSF, ainsi que les versions traduites, at www.pentair.com, or by scanning the así como versiones traducidas en www. peuvent être trouvées sur www.pentair.com, ou provided QR code.
  • Page 2: Important Safety Instructions

    This guide provides installation and operation instructions for this pump. • The pump is not submersible. Consult Pentair with any questions regarding this equipment. • The pump is capable of high flow rates; use caution when installing and Attention Installer: This guide contains important information about the programming to limit pumps performance potential with old or questionable installation, operation and safe use of this product.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS HAZARDOUS PRESSURE: STAND CLEAR OF PUMP TO MINIMIZE THE RISK OF INJURY DUE TO AND FILTER DURING START UP. SUCTION ENTRAPMENT HAZARD: Circulation systems operate under high pressure. When • A properly installed and secured ANSI/ASME A112.19.8 approved anti- any part of the circulating system (i.e.
  • Page 4: Table Of Contents

    Visit: www.pentair.com Fax: (800) 284-4151 TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..... INTRODUCTION ............. Home Dashboard INITIAL SETUP ............Create a Pentair Home Account Pairing Devices to your Account OPERATION ............Pump Dashboard Program Setup Device Settings Relays Direct Connect...
  • Page 5: Introduction

    The Pentair Home app is the perfect solution for remotely monitoring and controlling your pool equipment from anywhere. This guide provides instructions on creating an account and using Pentair Home to get the most out your Pentair Home account and your connected pool products.
  • Page 6: Initial Setup

    INITIAL SETUP Creating a Pentair Home Account 1. From your chosen smart device, download Pentair Home from the Google Play store (Android devices) or Apple app store (iOS ® ® ® ® devices). Note: Apple operating systems must be iOS 11 or later. Android ®...
  • Page 7: Pairing Devices To Your Account

    Pairing Devices to your Account Several smartphone functions will be used to successfully pair your pump to your Pentair Home account. Before signing into the app ensure: • Your smartphone's Bluetooth wireless technology is turned on ® • Your smartphone's location service is on • Pentair Home has Bluetooth permissions TO PAIR A PUMP TO YOUR ACCOUNT: 1.
  • Page 8: Operation

    OPERATION Pump Dashboard The Pump Dashboard is your pump's home page. Basic pump info, run status and programming can be viewed from this screen. If any pump alerts and problems are present they will also display at the top of this screen. 1− Device Settings: Tap to display the Device Settings screen.
  • Page 9: Program Setup

    Program Setup The pump allows you to create and customize up to 8 unique programs. The pump also features a default Quick Clean program that can be customized, but not renamed or deleted. 1- Schedule Enabled/Disabled Toggle: Tap to enable or disable a Schedule Program.
  • Page 10: Device Settings

    16- Device Security: Set a 4-digit PIN controlling access to pump controls. 10- Device Resets: Restore system defaults for all programs and device settings. 15- Remove Device: Remove the pump and pump relay devices from your Pentair Home account. INTELLIFLO3™ VSF and INTELLIPRO3™ VSF Variable Speed and Flow Pump User' s Guide...
  • Page 11: Relays

    1. Ensure your smartphone is within Bluetooth range of the pump, Bluetooth is enabled on your smartphone and Pentair Home has Bluetooth permissions. 2. At the pump, press the CONNECT button to enter pairing mode. The pump's CONNECT LED will blink blue.
  • Page 12: Priming Parameters

    Priming Parameters Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Priming Parameters All priming settings can be edited and set from this screen. Tap a specific setting on the right-side of the screen to edit. 1- Enabled/Disabled: ENABLED allows the pump to detect whether or not the system is properly primed for pump startup. If prime is not detected the pump will enter a priming cycle, based on the settings below.
  • Page 13: Thermal Mode

    Thermal Mode Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Thermal Mode Thermal Mode is intended to help protect the pump during freezing or near-freezing conditions. Note: Do not depend on this feature for freeze protection of the entire filtration system and pool. Certain situations could cause the pump to sense a different temperature than actual air temperature.
  • Page 14: Troubleshooting

    Stand closer to the pump when operating via connectivity issues Bluetooth ® Bluetooth. Restart the Pentair Home app. Adjust the pump antenna. Ensure smartphone permissions are given to the pump. Poor WiFi signal to router The WiFi antenna can be relocated from the top cover of the drive to a location with better WiFi signal.
  • Page 15: Alarms And Warnings

    The motor and drive are not able to reduce speed enough to protect themselves. Exceeded & Cut Off to prevent the drive from The motor will stop and Pentair Home will display this alarm. overheating. When the drive has cooled enough, it will automatically resume operation and attempt to run the requested program.
  • Page 16 WWW.PENTAIR.COM All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Apple® and App Store® are registered trademarks of Apple Inc. in the United States and/or other countries. iOS® is a registered trademark of Cisco Technology, Inc.

This manual is also suitable for:

Sta-rite intellipro3 vsf

Table of Contents