Pump Menu: Priming
PRIMING
DISABLED/ENABLED
MAX PRIMING TIME

Priming Features

PRIMED SENSITIVITY
DISABLED/ENABLED
PRIMING DELAY
DISABLED/ENABLED
SET SPEED
MAX PRIMING TIME
PRIMING RANGE
PRIMING DELAY
XF
®
INTELLIFLO
and INTELLIPRO
Default: Enabled
(1 min. to 30 min. hrs.) Default: 11 minutes
(1 - 100%) Default: 1
Default: ENABLED
(1 second - 10 minutes) Default: 20 seconds
Allows pump to automatically detect if pump if is primed for startup. The pump will speed
up to 1800 RPM and pause for 3 seconds - if there is enough water in the basket, the
Disabled / Enabled - Default: Enabled
pump will go out of priming mode and run the commanded speed.
Default: 3450 RPM
The priming speed can be set between 3450 RPM and 2350 RPM. If the pump is on an
equipment pad that is close to the water level, it will not need to run at 3450 RPM to successfully
prime. The setting can be lowered to prevent running at a higher speed than necessary.
Day to day factors (i.e. local ambient pressure, water/air temperatures, amount of
water retained from last system run) can effect priming performance. Because of the
frequently changing nature of these factors the priming speed should be set high enough
to accommodate environmental and mechanical changes to ensure that the pump can
successfully prime. Finding the most effective and efficient speed for your specific needs
may take careful testing and evaluation of priming performance.
Default: 11 minutes
The maximum priming time can be set from 1 - 30 minutes. This setting is the amount of
time the pump will try to prime before it gives a priming error. If this occurs, fill the pump
basket with water and restart the pump.
Default: 5
Priming range can be set from 1-10. The smaller the range, the more water the pump
has to be moving to detect that it is primed. At larger ranges, the pump will detect that it
is fully primed while moving less water. If the range is set too high, then the pump may
exit Priming mode before it has fully primed. The range will automatically adjust with the
priming set speed because the flow rates of the pump will be lower at lower speeds.
Default: 20 seconds
Priming delay can be set from 1 second to 10 minutes.
If the pump does not have enough water after the automatic priming mode, the pump will
increase to the Maximum Speed (see Pump Settings on page 8) and run for 20 seconds
(or for the time set).
You may need to increase the priming delay to allow the system to stabilize before the
pump starts running speeds. If pump continues to show a priming error, increasing the
priming delay time might correct this issue.