Setting Speeds In Manual Mode; Setting Speeds In Egg-Timer Mode; Setting Speeds 1-8 In Schedule Mode - Pentair INTELLIFLOXF Installation And User Manual

Variable speed pump
Hide thumbs Also See for INTELLIFLOXF:
Table of Contents

Advertisement

MENU
Pump Menu: Speeds 1-8
SPEED 1-8
Speed 1 (1-4)
Set Speeds in Manual Mode
(Speeds 1-4 Only)
1. Press Menu.
Speed 5 (5-8)
2. Use Up or Down arrows to scroll to "Speed 1-8",
then press Select.
3. Use Up or Down arrows to find the speed (1-4) you
wish to program, then press Select.
4. Speeds 1-2 default setting is Manual. Speeds 3-4
default setting is Egg Timer. To set a speed in Manual
Down arrow ("Set Speed" will
mode, press the
display) and press Select to change. Use the Up or
Down arrow to adjust speed.
5. Press Save to save the new speed setting.
Set Speeds in Egg-Timer Mode
(Speeds 1-4 Only)
1. Press Menu.
2. Use Up or Down arrows to scroll to "Speed 1-8", the
press Select.
3. Use Up or Down arrow to find the speed (1-4) you
wish to program, then press Select.
4. Use the Up or Down arrows to scroll to "Egg-Timer",
then press Select.
5. To set a speed in Egg-Timer mode, press the Down
arrow ("Set Speed" will display) and press Select to
change. Use the Up or Down arrow to adjust speed.
6. Press Save to save the new speed setting.
7. Now press the Down arrow ("Set Time" will display)
and press Select to change. Use the Up or Down
arrows to adjust the time.
8. Press Save to save the new time setting.
12:15p
Manual
Set Speed
Manual Mode Menu Screen
Manual
Schedule
Egg Timer
Disabled
Schedule
12:15p
Egg Timer
Time
Egg Timer Menu Screen
XF
®
INTELLIFLO
and INTELLIPRO
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Speeds 1-8 in Schedule Mode
Set Stop Time
In Schedule mode, Speeds 1-8 can be programmed
Set Speed
Time
to run a certain speed at a certain time of day. To run
a scheduled speed, press Start/Stop. The screen will
Default: Disabled
display "Running Schedules" when it is ready to run
Set Speed
a scheduled speed. If Start/Stop is pressed while a
Set Start Time
scheduled speed is running, the pump will stop running
Set Stop Time
the scheduled speed. The pump will not continue to
run the scheduled speed until the Start/Stop button is
pressed again.
1. Press Menu.
2. Use Up or Down arrows to scroll to "Speed 1-8",
then press Select.
3. Use Up or Down arrows
speed you wish to set and schedule.
4. Press Select (display will be highlighted) and scroll
to "Schedule".
5. Press Save.
6. Press
Down arrow ("Set Speed" will display) and
press Select to change. Use the Up or Down arrow
to adjust speed.
7. Press Save to save the new speed.
8. Press the
Down arrow again, "Set Start Time" will
Press Select -
display.
minute column.
9. Use the Up or Down arrow to change the time and
the
Left or Right
arrow to move cursor from minutes
to hours.
10. Press Save to save the new start time setting.
11. Press
Down arrow - "Set Stop Time" will display.
Press Select. Repeat Steps 8-9 to set stop time.
12. Press Save to save the new stop time setting.
13. Press Start/Stop.
The pump will prime and begin to run the programmed
schedule at the specified start time.
When running in Schedule or Egg Timer mode, the
countdown time (T 00:01) showing the hours and minutes
remaining is displayed.
XF
®
Variable Speed Pump Installation and User' s Guide
and press
Select
for the
the cursor will highlight the
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intelliproxf

Table of Contents