Drive Assembly Removal and Installation

FIRE and BURN HAZARD - The pump motor may run at a high temperatures. To reduce the risk of fire, do not allow leaves, debris,
or foreign matter to collect around the pump motor. To avoid burns when handling the motor, shut off the motor and allow it to cool
for 20 minutes before servicing. The pump provides an automatic internal cutoff switch to protect the motor from heat damage during operation.
To avoid electrical hazard, do not remove the four tamper proof screws from the motor assembly.
To remove the drive and control panel from the
motor assembly:
Press Start/Stop to stop the pump and disconnect
1.
all power to the pump at the circuit breaker.
Disconnect any digital inputs or communication
2.
cables from the pump.
Remove the four Phillips-head Drive Cover Screws
3.
from the outer corners of the keypad.
Unplug the keypad from the drive and set it to the
4.
side.
Remove the three Phillips-head Drive-to-Motor
5.
Screws, located inside the drive.
Lift the drive from the motor and set aside.
6.
Note: Be careful not to remove the gasket
between the drive and motor. It is critical in
keeping moisture out of the drive and motor.
Replace the gasket if damaged. Do not
reassemble with a damaged or missing gasket.
Drive
Cover
Drive Cover
Screws (4x)
#10-24 X 2" Phillips
Head Screws,
Drive-to-Motor (3x)
Drive-to-Motor
Gasket
Motor Post
Caps (3x)
Drive
Connector
Drive Assembly and Removal
To install the drive assembly onto the motor
assembly:
Ensure all power to the pump and any automation
1.
controls are turned off at the circuit breakers.
Ensure that the gasket between the drive and motor
2.
is in place. It is critical in keeping moisture out of the
drive and motor. Replace the gasket if damaged. Do
not reassemble with a damaged or missing gasket.
Verify that the three orange motor post caps are
3.
in position before placing the drive on the motor
assembly.
Align the drive assembly with the motor adapter and
4.
seat the drive on the motor assembly.
Secure and tighten the drive assembly with the three
5.
Phillips-head Drive-to-Motor Screws.
Plug the keypad back into the drive.
6.
Place the keypad in the desired orientation on the
7.
drive and reinstall the four Drive Cover Screws in the
corners of the drive.
XF
®
INTELLIFLO
and INTELLIPRO
Note: Ensure that the keypad cable is not being
pinched between the drive and keypad.
XF
®
Variable Speed Pump Installation and User' s Guide
23

Advertisement