5.1 *Function Description

The built-in thermal recorder applied in the monitor supports both the American and international
standard
wide
FHR1/DFHR/FHR2//FHR3/TOCO/ eFHR /AFM/HR/SpO
FHR2/FHR3/eFHR/HR/SpO2; monitoring information: patient's ID, patient's name, date, time,
speed(i.e. printing speed), FHR2 offset, FHR3 offset, HR, SpO
marks: AUTO-zero symbol, MFM mark, event mark, fetal stimulation mark, alarm indicator, SOV
indicator, US1, US2 and US3 signal weak alarm indicator, transducer wireless signal weak indicator.
The monitor supports some other functions listed below:
Auto start printing: If the function is enabled, the recorder starts printing automatically when
new monitoring starts (the START key is pressed). Otherwise you have to press the PRINT key to
start printing.
Printing timer: The printing timer determines the elapsed time for each print. This time is
adjustable. Refer to 5.2.3 Changing the Print Timer.
Remaining time indicating: If the printing timer is set, a process indicator
the status window after printing starts, with the remaining time shown in it. When the time is up,
the monitor gives three "Do" tones and flashes the indicator.
Fast printing: The recorder prints the data saved in the monitor at a high speed (up to
18.5mm/s).
Data Caching: When the paper drawer runs out of paper or when it is open, the recorder stops
printing. The data from this time on (at most 60 minutes) will be temporarily saved in the internal
memory. When new paper is loaded and/or the drawer is closed, the saved data will be printed
out at a high speed. When the saved trace has been printed out, the recorder switches back to
continue printing the current data at the normal speed automatically.
NOTE:
1 When the monitor is switched off, the data in the internal memory will be lost.
2 If a printing timer is set, and the time is out when the paper runs out, the CTG analysis
result may disaccord with the printout. Therefore, reload the paper in time to avoid paper
shortage.
FHR2/FHR3 offset: You can set the offset of the FHR2/FHR3 trace to separate the two FH traces
on the screen and the recorder paper. Refer to 7.4.4 Changing FHR2 Offset and 7.5.4 Changing
FHR3 Offset.
Print self-check: The recorder prints a baseline for self-checking when the monitor is switched
on.
Paper advance: When printing stops, press the paper advancing key
paper, making sure the paper has a perforation outside the drawer and is easy to be torn off.
Separation Printing: If the function is enabled, the twins/triplets FHR traces in real time or saved
in the monitor can be printed separately. During real time monitoring, the recorder will print the
FHR trace at a normal speed and then quickly print traces of FHR2/FHR3, and in the end print the
grading result.
NOTE:
The paper advancing key is invalid in the process of printing and paper advancing.
014_14.1_F15_Series_User_Manual
recorder
paper.
It
prints
synchronously
traces; trace marks: FHR1//DFHR/
2
, TEMP; SYS/DIA/MAP/PR; event
2
- 68 -
Printing
monitoring
traces:
appears in
to advance the
84/202

Advertisement

Table of Contents
loading

Table of Contents