Sign In
Upload
Manuals
Brands
EDAN Manuals
Medical Equipment
F15 Series
EDAN F15 Series Manuals
Manuals and User Guides for EDAN F15 Series. We have
2
EDAN F15 Series manuals available for free PDF download: User Manual, Service Manual
EDAN F15 Series User Manual (202 pages)
Fetal & Maternal Monitor
Brand:
EDAN
| Category:
Monitor
| Size: 5.25 MB
Table of Contents
Table of Contents
3
Features
9
Safety Precautions
11
Chapter1 Safety Guidance
17
Intended Use/Indications for Use
17
Safety Information
18
Protecting Personal Information
18
Instruction for Safe Operation
19
Security
19
Definitions and Symbols
20
Chapter2 Installation
24
Opening the Package and Checking
24
Installing Battery
24
Patient Transfer Within the Hospital
25
Installing Monitor
25
Loading Recorder Paper
25
Connecting Power Cable
27
Installing Transducer Holder Bracket
28
Chapter3 Basic Operation
30
Overview
30
Left Panel
30
Right Panel
31
Rear Panel
32
Bottom Panel
32
Indicators
33
Transducers and Cables
33
Transducers
34
Remote Event Marker(Optional for F15 Only)
37
DECG Cable
38
DECG-IUP Integrated Cable
38
Fetal Spiral Electrode
38
IUP Catheter
39
ECG Cable
39
Spo Sensor
39
NIBP Cuff
40
TEMP Sensor
40
FT20 Telemetry Transmitter
40
Charging FT20 Telemetry Transmitter
41
Displaying of FT20 Telemetry Transmitter
41
Power Key
41
Wireless Transducer
41
Charging Wireless Transducer
41
Displaying of Wireless Transducer
42
Close Wireless Transducer
43
Monitor the Ambulatory Patient
44
Operating and Navigating
44
Screen Elements
44
Main Menu
49
Quick Setup
49
Monitoring Interface
50
Interface Display
50
Switch Display Mode
50
Background Color Switch
51
Changing Numeric Window Position (Suitable for AP/IP Configuration Models)
51
Changing Time Scale
51
Monitoring Numerics
52
Fetal Monitoring
52
Maternal Monitoring(F15)
56
Trace Control Tools
58
Data Saving
59
Searching for a File
59
File Management (Optional)
60
Reviewing
62
CTG Analysis
62
Marking a Note
64
Introduction of FTS-3 Fetal Telemetry System
65
Chapter4 Alarms
66
Alarm Classification
66
Alarm Delay
66
Audible Alarm
66
Visual Alarm
67
Choosing the Alarm Display Form
68
Changing the Alarm Volume
68
Choosing Alarm Silence Duration
68
Choosing Signal Loss Delay
68
Pausing or Resetting the Alarm
68
To Switch Individual Measurement Alarms on or off
69
Changing the Alarm Limits
69
Switching Transducer Unplugged on or off
69
Switching CTG Alarm on or off
70
Reviewing Alarms
70
Alarm Treatment Measures
71
Testing Alarms
71
Patient Alarm Defaults
71
Alarm Messages
73
Fetal Monitoring Alarm Messages
73
Maternal Monitoring Alarm Messages
78
Technical Alarm Messages
82
Alarm Bilateral Control
83
Chapter5 Printing
84
Function Description
84
Printing Configuration
85
Switching Auto Start Printing on or off
85
Choosing the Paper Speed
85
Changing the Print Timer
85
Switching Print Self-Check on or off
85
Changing Printing End Volume
85
Changing Title Print Cycle
86
Switching Separation Printing on or off
86
Switching Maternal Monitor Information on or off
86
Understanding Recorder Paper Printout
86
Chapter6 Pre-Monitoring Preparation
89
Switching on the Monitor
89
Checking the Recorder Paper
89
Adjusting the Screen Angle
90
Setting Screen Brightness
91
Setting Date and Time
91
Connecting Transducers
92
Placing Accessories in the Holder
92
Adjusting the Volume
92
Chapter7 Fetal Monitoring
94
Confirming Fetal Life
94
FHR Monitoring FHR with Ultrasound
94
Monitoring FHR with Ultrasound Transducer
95
Changing the FHR Alarm Delay
97
Testing US Transducers
97
Monitoring FHR with DECG
98
Preparing the Patient's Skin Prior to Placing Electrodes
98
Directions for Using Fetal Spiral Electrode
98
DECG Monitoring
99
Changing DECG Beep Volume
100
DECG Gain and Display
101
Switching the Artifact Suppression on or off
101
Detaching the Fetal Spiral Electrode
101
Monitoring Twin Fhrs
101
Monitoring Twins Externally
101
Monitoring Internally
102
Signals Overlap Verification (SOV)
102
Changing FHR2 Offset
102
Monitoring Triple Fhrs
103
Monitoring Triplets Externally
103
Monitoring Internally
103
Signals Overlap Verification (SOV)
103
Changing FHR3 Offset
103
Monitoring Uterine Activity Externally
104
TOCO Monitoring
104
Changing the UA Baseline
105
Testing TOCO Transducers
105
Monitoring Uterine Activity Internally
106
Parts Required
106
Directions for Use of IUPC
106
IUP Monitoring Procedure
108
Monitoring Fetal Movement
108
Auto Fetal Movement (AFM) Monitoring
108
Enabling or Disabling AFM Monitoring
109
Choosing AFM Mode
109
Choosing FM Source
109
Manual Fetal Movement (MFM) Monitoring
109
Changing MFM Volume
109
Start Monitoring
110
Inputting Maternal Information (Mat. Info)
110
Auto ID
110
Changing Maternal Information
110
ID Entry with a Scanner
111
Switching Mat. Info Inputting on or off
111
Chapter8 Maternal Monitoring
112
Maternal ECG Monitoring
112
Introduction
112
How to Place 3-Lead ECG Cables
113
ECG Monitoring
114
Changing ECG Gain
115
Maternal Spo Monitoring
115
Monitoring Procedure
117
Enabling Spo Trace Printing
117
Assessing the Validity of a Spo Reading
117
Signal Intensity)
118
Spo 2 Relevant Data for Reference
118
Maternal HR Monitoring
119
Introduction
119
Choosing HR Source
119
Monitor HR with Electrode Sleeve
120
Changing HR Beep Volume
121
Enabling HR Trace
122
Signals Overlap Verification
122
Maternal NIBP Monitoring
122
Introduction
122
How to Apply NIBP Cuff
124
Measurement Procedures
125
Auto Measurement
125
Manual Measurement
126
Changing NIBP Unit
126
Choosing NIBP Printing Mode
127
Calibrating NIBP
127
Maternal TEMP Monitoring
127
Monitoring Procedure
127
Changing TEMP Unit
128
Chapter9 Monitoring Mother and Fetus Using FECG
129
Confirming Fetal Life
129
Start Monitoring
129
Introduction
129
Parts Required
130
Skin Preparation
130
Electrode Placement
131
Connecting the ECG Leads to the Electrodes
132
Placing the Transducer
132
Electrode Checking
133
Changing FECG Gain
133
Changing ECG Gain
134
Changing FECG Beep Volume
134
Monitoring Interface
134
Chapter10 after Monitoring
136
Completing Monitoring
136
Switching off
136
Chapter11 Maintenance And Cleaning
137
Maintenance
137
Maintaining Inspection
137
Maintenance of Monitor
137
Maintenance of Wired and Wireless Transducers
137
Storage of Recorder Paper
138
Cleaning of Recorder
138
Maintaining the Battery
138
Checking Battery Performance
139
Storing the Battery
139
Cleaning
139
Cleaning the Monitor
140
Cleaning the Reusable Accessories
141
Cleaning the Ultrasound Transducer
141
Cleaning the NIBP Cuff
141
Cleaning the ECG Cable Assembly
142
Cleaning the TOCO Transducer and Spo2 Sensor
142
Cleaning the TEMP Sensor
142
Disinfecting
142
Disinfecting the Monitor
143
Disinfecting of Reusable Accessories
143
Disinfecting the Ultrasound Transducer
143
Disinfecting the NIBP Cuff
144
Disinfecting the ECG Cable Assembly
144
Disinfecting the TOCO Transducer and Spo2 Sensor
144
Disinfecting the TEMP Sensor
144
Cleaning and Disinfecting Other Accessories
144
Storage
144
Chapter12 Warranty And Service
146
Contact Information
146
Appendix 1 Product Specifications
147
A F15 Fetal/Maternal Monitor
147
A1.1 Environmental Specifications
147
A1.2 Physical Specifications
147
A1.3 Performance Specifications
149
A1.4 Recorder Specifications
154
A1.5 Rechargeable Lithium-Ion Battery
155
A1.6 WIFI Specifications
156
A1.7 NFC Specifications
156
A1.8 Interface Specifications
157
A1.8.1 USB Interfaces
157
A1.8.2 Wired Network Interface
157
A1.8.3 HDMI Interface
157
A1.8.5 DB15 Interface
157
Appendix 2 Signal Input/ Output Connector
158
Appendix 3 Troubleshooting
159
A3.1 no Display
159
A3.2 no Touch Response
159
A3.3 Noise
159
A3.4 Recorder Error
159
A3.5 Trouble with Ultrasound FHR Monitoring
160
A3.6 Troubles with DECG Monitoring
160
A3.7 Troubles with Contractions Monitoring (External)
161
A3.8 Troubles with Contractions Monitoring (Internal)
161
A3.9 Trouble with ECG Monitoring
161
A 3.10Troubles with HR Monitoring with Electrode Sleeve
162
A3.10 no NIBP and Spo2 Results
163
A3.11 Monitor Unable to be Charged
163
Appendix 4 Ultrasound Intensity and Safety
164
A4.1 Ultrasound in Medicine
164
A4.2 Ultrasound Safety and the ALARA Principle
164
A4.3 Explanation of MI/TI
164
A4.3.1 MI (Mechanical Index)
164
A4.3.2 TI (Thermal Index)
164
A4.3.3 Measurement Uncertainty
165
A4.4 Prudent Use Statement
165
A4.5 References for Acoustic Output and Safety
165
A4.6 Transducer Acoustic Output Parameters List
166
A4.6.1 Test of Wired Transducer(F15)
166
A4.6.2 Test of Wireless Transducer(F15 Air)
168
A4.6.3 Standard Parameter Equal Contrast List
170
Appendix 5 Abbreviation
172
Appendix 6 Ordering Information
174
Appendix 7 EMC Information
177
A7.1 Electromagnetic Emissions
177
A7.2 Electromagnetic Immunity
178
A7.3 Electromagnetic Immunity
181
A7.4 Recommended Separation Distances
183
Appendix 8 Limitations of Ultrasonic Monitoring
184
A8.1 How Does Ultrasound Work
184
A8.2 Artifacts in Fetal Heart Monitoring
184
A8.3 Audio Output and Screen Reading
186
Appendix 9 WI-FI Networking and Instructions
188
A9.1 General
188
A9.2 Scope of Application
188
A9.3 Network Installation Process
189
A9.4 Site Survey and Network Requirements
189
A9.5 Network Design and Implementation
191
A9.5.1 Networking Scheme
191
A9.5.2 Wireless Model Network Design
196
A9.6 Continuous Transmission from Disconnection of Wireless Transducer
200
A9.7 Connecting the Monitor to MFM-CNS/ MFM-CNS Lite
201
Advertisement
EDAN F15 Series Service Manual (80 pages)
Brand:
EDAN
| Category:
Medical Equipment
| Size: 5.07 MB
Table of Contents
Table of Contents
4
Chapter 1 Safety Guidance
7
Introduction
7
General Information
7
Safety Precautions
8
Definitions and Symbols
12
Chapter 2 Installation
16
Environmental Requirements
16
Electrical Requirements
17
Safety Requirements
17
Installing the Monitor
17
Installing the Monitor on a Flat Surface
17
Mounting the Monitor on a Wall
18
Installing the Monitor on Trolley
19
Connecting to AC Power
20
Chapter 3 Functional Checks
21
Switching on Check
21
LCD Screen Check
21
Touch Screen Check
21
Printing Check
22
Alarms Check
22
Chapter 4 System Configuration
23
Opening System Setup Menu
23
Entering Demo Mode
23
Reloading Default Settings
23
Clearing Data
24
Checking Product Information
24
Calibrating Touch Screen
24
Changing the Device no
25
Changing Net Version
25
Configuring 485 Wireless Network
25
Configuring for Ethernet Connecting
26
Changing Trace Width
27
Changing Paper Style
27
Changing the Language
27
Changing FHR Algorithm
28
Pressure Verification
28
NIBP Leak Test
28
NIBP Calibration
28
Chapter 5 Maintenance
30
Maintenance Inspection
30
Maintenance of the Monitor
30
Maintenance of the Transducers
31
Maintenance of the Recorder
31
Chapter 6 Principle Introduction
32
System Principle Block Diagram
32
Main Control Board
33
Bottom Interface Board
34
AC-DC Power Board
35
DC-DC Transfer Board
36
IM X12 Parameter Board(Wired Model Only
37
Edan Transducer Socket Board (Wired Model Only)
39
NELL Transducer Socket Board (Wired Model Only)
39
Wireless Charging Board (Wireless Model Only)
40
Interface
41
DB15 Interface
41
Antenna
41
RJ45 Interface
41
HDMI Interface
42
Chapter 7 Troubleshooting
43
Monitor Booting Failures
43
Display Failures
43
Touch Screen Failures
44
Sound Failures
44
Recorder Failures
44
Network Failures
45
Alarm Failures
45
Alarm Failures
46
FHR/TOCO Monitoring Failures
46
ECG Monitoring Failures
46
Spo2 Monitoring Failures
47
NIBP Monitoring Failures
47
TEMP Monitoring Failures
48
Chapter 8 Modules' Malfunction Verification
49
Verifying Malfunction of the Main Control Board
49
Verifying Malfunction of the IM X12 Parameter Board
53
Verifying Malfunction of Lower Case Interface Board
54
Verifying Malfunction of AC-DC Power Board
55
Verifying Malfunction of EDAN Transducer Socket Board (Wired Model Only)
56
Verifying Malfunction of NELL Transducer Socket Board (Wired Model Only)
57
Verifying Malfunction of Wireless Charging Board
57
Chapter 9 Disassembling the Monitor
59
Tools Required
59
Disassembling the Main Unit
59
Disassembling the Lower Assembly
61
Replacing the DC-DC Transfer Board
61
Replacing the Fan
62
Replacing the Power Module
63
Replacing the WIFI Module
64
Replacing the Main Control Board
64
Replacing the IM X12 Parameter Board (Wired Model Only)
65
Replacing the Loudspeaker
66
Replacing the Transducer Socket Board (Wired Model Only)
67
Replacing the Bottom Interface Board
67
Replacing the Printhead
68
Replacing the AP Module (Wireless Model Only)
69
Replacing the Wireless Transducer Bracket (Wireless Model Only)
69
Disassembling the Upper Assembly
70
Replacing the LCD Assembly
70
Chapter 10 Periodic Tests
71
Safety Tests
71
Performance Tests
71
FHR Performance Test
71
TOCO Performance Test
72
ECG Performance Test
72
Spo2 Performance Test
73
NIBP Performance Test
73
TEMP Performance Test
73
FECG Performance Test(Wireless Model Only
74
Appendix 1 Renewal Parts
76
Appendix 2 Connecting to ob Tracevue System
77
Advertisement
Related Products
EDAN F6 Express
EDAN F9 Express
EDAN FTS-3
EDAN Acclarix AX15
EDAN Acclarix AX18
EDAN Acclarix AX2
EDAN Acclarix AX2 Exp
EDAN Acclarix AX25
EDAN Acclarix AX28
EDAN Acclarix AX3
EDAN Categories
Medical Equipment
Diagnostic Equipment
Monitor
Measuring Instruments
All in One Printer
More EDAN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL