Valve Specifications - Pentair FLECK 2510 Service Manual

Aio control valve
Hide thumbs Also See for FLECK 2510:
Table of Contents

Advertisement

IMPORTANT PLEASE READ:
• The information, specifications and illustrations in this manual are
based on the latest information available at the time of release. The
manufacturer reserves the right to make changes at any time without
notice.
• This manual is intended as a guide for service of the valve only. System
installation requires information from a number of suppliers not known
at the time of manufacture. This product should be installed by a
plumbing professional.
• This unit is designed to be installed on potable water systems only.
• This product must be installed in compliance with all state and
municipal plumbing and electrical codes. Permits may be required at
the time of installation.
• It is established that when daytime water pressure exceeds 80 psi (5.5
bar), the maximum pressure rating of 125 psi (8.6 bar) can be exceeded.
A pressure regulator must be installed on this system or warranty is
voided.
• Do not install the unit where temperatures may drop below 32°F (0°C)
or above 120°F (52°C).
• Do not place the unit in direct sunlight. Black units will absorb radiant
heat, increasing internal temperatures.
• Do not strike the valve or any of the components.
• Warranty of this product extends to manufacturing defects.
Misapplication of this product may result in failure to properly condition
water, damage to product, or personal injury.
• A prefilter should be used on installations in which free solids are
present.
• In some applications local municipalities treat water with Chloramines.
High Chloramine levels may damage valve components.
• Correct and constant voltage must be supplied to the controller to
maintain proper function.
• The system is intended to treat only potable quality water. It is not
intended as the permanent primary treatment of water from a source
that is contaminated, such as from radon, pesticides, insecticides,
sewage or wastewater.
• This system is not intended for use by persons (including children) with
reduced physical, sensory, or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
• Children shall not play with the system.
• Cleaning shall not be made by children without supervision.

VALVE SPECIFICATIONS

Valve Material
Fiber-reinforced polymer
Inlet/Outlet
3/4", 1", or 1-1/4
NPT/BSP/Sweat
Cycles
3 or 5
Flow Rates (50 psi inlet) valve only
Continuous
19 GPM (4.3 m³/h)
15 psi drop
Peak
25 GPM (5.5 m³/h)
25 psi drop
Cv
4.8
flow at 1 psi drop
Max Backwash
17 GPM (3.9 m³/h)
25 psi drop
Dimensions
Distributor Pilot
1.05" O.D. (26.7 mm)
Drain Line
1/2" NPTF Quick-Connect
Injector System
1600, 1650
Mounting Base
2.5" - 8 NPSM
Height from Top of
7.5" (191 mm)
Tank
Riser Tube Diameter
3/4" (19 mm)
Riser Height
1/4" below top of tank
Additional Information
Electrical Rating
24/110/220V
Pressure (Hydrostatic) 300 psi
(20 bar)
Pressure (Working)
20-125 psi
(1.4-8.5 bar)
Temperature
34-110°F (1-43°C)
Cold Water Valve:
FLECK
50/60 Hz
2510 AIO SXT Service Manual
• 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents