User instructions
Override users
Opening
Change code
This user manual describes the standard programming. According to such programming and
unless different requests made while ordering the product, an opening can be performed by
entering single users codes (no dual mode) and without time delay. Thus, the user manual must
be adapted according the configuration selected.
It is strongly recommended to change the default codes before using the lock.

Overview functions

Lock opening
After entering an opening code, it is possible to open the lock within 3 seconds. It's no necessary
instead with motorized locks: in this case indeed, the motor moves the bolt which remains in
opening position for about 8 seconds before returning in closing position. In the manual closing
version instead, the bolt can be closed by pressing
Penalty
Four consecutive wrong codes initiate a four-minutes penalty time. During this period, LCD
displays the message "PENALTY" and no operation is allowed.
For class C, the minimum penalty time is of 5 minutes.
Time Delay
Programmable time delay in between 0 and 99 minutes. Programmable opening window in
between 1 and 19 minutes.
Dallas keys
It can be programmed for any lock. Available as option for Manager and users (not for Master).
TechMaster keypad only works with Dallas keys created by TECNOSICUREZZA. Upon express
request, the keypad can be set in order to work also with different Dallas key models.
Power supply
Lock can be powered with:
 an ALKALINE 9V battery located in the battery compartment below the keypad;
 an internal battery box provided by Tecnosicurezza (6 ALKALINE 1.5 batteries);
8 of 28
Test mode
Check system Information
Standard users
Opening
Set opening extension, if enabled
Set immediate time lock, if enabled
Code changing