Enable Character

Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the Enable
2. Use the ASCII Chart in
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING on
5. Scan the appropriate two alphanumeric characters from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea-
ture.
Table 11 - Enable Character Setting Examples
STEP
1
Desired character/value
Hex equivalent from ASCII Chart
2
on page 341
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ENABLE CHARACTER VALUE SETTING
Scan two characters from
5
Appendix D
6
Scan ENTER/EXIT PROGRAMMING MODE
NOTE: Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit data
is not recognized when the option " Data Bits" on page 38 has been set as 7
Data Bits.
Character is not used (not available).
Appendix F
ter/value.
Mode.
that represent the desired character/value determined above. The second charac-
ter will cause a two-beep indication.
ACTION
to find the hex equivalent for the desired charac-
EXAMPLES
'e'
'}'
0x65
0x7D
'6' and '5' '7' and 'D'
'4' and '5'
RS-232/USB COM PARAMETERS
.
page 48
Appendix D
Enable Command
'E'
Not Used
0x45
0xFF
'F' and 'F'
PRODUCT REFERENCE GUIDE
,