Code 93 Check Character Transmission; Code 93 Length Control - Datalogic Gryphon 2D Series Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for Gryphon 2D Series:
Table of Contents

Advertisement

ENTER/EXIT PROGRAMMING MODE

Code 93 Check Character Transmission

This feature enables/disables transmission of an optional Code 93 check character.
$CC9CT00
Code 93 Check Character Transmission = Send

Code 93 Length Control

This feature specifies either variable length decoding or fixed length decoding for the
Code 93 symbology.
Variable Length:
Fixed Length:
$CC9LC00
Code 93 Length Control = Fixed Length
192
GRYPHON™ I GD/GBT/GM4500
For variable-length decoding, a minimum length may be set.
For fixed-length decoding, two different lengths may be set.
Code 93 Check Character Transmission = Don't
Send
$CC9CT01
Code 93 Length Control = Variable Length
$CC9LC01
1D SYMBOLOGIES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents