LED AND BEEPER INDICATORS

Silent Mode

If needed, audible indications can be disabled by scanning the labels below.
Please note that some important audible notifications are not muted in silent mode and
other notifications are replaced by vibration or visual indications.
All changes in audible notifications are summarized here:
SilentModeON
Silent Mode = Disable

RGB Good Read Enable

Specifies whether the RGB good read indicator is enabled or disabled.
$CRBGE00
RGB Good Read = Enable
Good Read beep is replaced with vibration
Power on beep is replaced with vibration
Connection / Disconnection / out of radio range beeps are replaced with blue LED
and vibration
Error beep, RF Error/timeout beeps, chirp beeps are replaced with red 3GL and
vibration
Battery beeps, programming labels, and RF paging beeps are not muted
ENTER/EXIT PROGRAMMING MODE
Silent Mode = Enable
SilentModeOFF
RGB Good Read = Disable
$CRBGE01