ENTER/EXIT PROGRAMMING MODE

Code 128 Quiet Zones

This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are
blank areas at the ends of a bar code and are typically 10 times the width of the narrow-
est bar or space in the label.
$CC8LO00
Code 128 Quiet Zones = Quiet Zone on one side
$CC8LO02
Code 128 Quiet Zones = Auto
$CC8LO04

Code 128 Length Control

This feature specifies either variable length decoding or fixed length decoding for the
Code 128 symbology.
Variable Length:
Fixed Length:
$CC8LC00
Code 128 Length Control = Fixed Length
150
GRYPHON™ I GD/GBT/GM4500
Code 128 Quiet Zones = Virtual Quiet Zones on two sides
For variable-length decoding, a minimum length may be set.
For fixed-length decoding, two different lengths may be set.
Code 128 Quiet Zones = No Quiet Zones
$CC8LO01
Code 128 Quiet Zones = Quiet Zones on two sides
$CC8LO03
Code 128 Length Control = Variable Length
$CC8LC01