Carrier Access Wide Bank 28 DS3 User Manual page 384

Hide thumbs Also See for Wide Bank 28 DS3:
Table of Contents

Advertisement

TL1 Commands and Messages
TL1 Automatic Messages
Table 2-1 Alarm and Event Message Parameters (Continued)
Access
Report
Identifier
Message
Type
DS1-{01-28}
REPT ALM
REPT ALM
REPT EVT
Not
Reported
DS1-CARD-
REPT ALM
{1-7}
DS1-CARD-
REPT ALM
SPARE
DS1-CARD-
REPT ALM
MSO-{1-7}
DS1-CARD-
REPT ALM
MSO-SPARE
9-110
Interface
Default
Service
Type
Notifi-
or Con-
cation
dition
Code
Effect
Code
EQPT
MN
NSA
T1
MN
NSA
MJ
SA
MJ
SA
MJ
SA
T1
EQPT
MJ
SA
MJ
SA
EQPT
MN
NSA
EQPT
MN
NSA
EQPT
MN
NSA
Condition Type
INT
BER-SD
BER-SF
FAILTOSW
LOS
T-CVL
T-ESL
WKSWPR
WKSWBK
ACTLPBK
INHLPBK
INHSWPR
INHSWWKG
LPBKEQPT
LPBKLINE
LPBKMETALLIC
PROTNA
FAILTOSW
IMPROPRMVL
IMPROPRMVL
IMPROPRMVL
IMPROPRMVL
July 2004
Condition Description
Internal Hardware Fault or Failure
Signal Degrade
Signal Fail
Failed to Switch
Loss of Signal
Threshold Violation - CV Line
Threshold Violation - Errored
seconds line
Working Unit Switched to Protect
Unit
Working Unit Switched Back to
Working
Loopback send code is Active
Loopdetect Off
Facility protection not enabled
Equipment protection not enabled
Equipment loopback
Line loopback
Metallic loopback
Protection unit is not available
Multiple MSO Card Removal
Improper Removal
Improper Removal
Improper Removal
Improper Removal
Wide Bank 28 DS3 - Release 2.4