Example:
Response:
Example:
Response:
Wide Bank 28 DS3 - Release 2.4
RTRV-T1:tid:DS1-2:ctag;
This command retrieves the configuration for DS1 #2.
tid 2001-08-04 11:51:58
M
ctag COMPLD
"DS1-02::AISF=Y,CMDMDE=FRCD,DLCID=DS1 2,
FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LBO=1,LINECDE=B8ZS,
OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,NALMNR"
;
RTRV-E1:tid:E1-1:ctag;
This command retrieves the configuration for E1 #1.
tid 2001-08-04 11:47:18
M
ctag COMPLD
"E1-01::AISF=Y,CMDMDE=FRCD,DLCID=E1 1,
FLMDE=BOTH,FMT=UNFR,IDLE=AIS,LINECDE=HDB3,
OMODE=NORM,RVRTFLAG=UNLCKD:IS-EQ,"
;
Field
Description
AISF
Indicates whether failed signal from upstream should be replaced by
AIS. This is hard-coded to Y in the Wide Bank.
CMDMDE
Indicates command execution mode. This is hard-coded to FRCD in
the Wide Bank. This means that existing parameter settings may be
overridden in order to execute the command.
DLCID
The DS1 or E1 digital loop carrier system identifier. This is a string
of ASCII characters and has a maximum length of 32 characters.
FLMDE
Indicates the fault locate mode. This is hard-coded to BOTH in the
Wide Bank.
FMT
Indicates DS1 digital signal format. This is hard-coded to UNFR in
the Wide Bank.
IDLE
Indicates the signal inserted for idle DS1. This is hard-coded to AIS
in the Wide Bank.
LBO
Indicates the line buildout setting. Values are 1-6. Line Build Out
(length) applies to T1 only (E1 has no LBO).
• 1 – DSX (0-110 ft.)
• 2 – DSX (110-220 ft.)
• 3 – DSX (220-330 ft.)
• 4 – DSX (330-440 ft.)
• 5 – DSX (440-550 ft.)
• 6 – DSX (550-660 ft.)
July 2004
TL1 Commands and Messages
TL1 Command List
9-49