Carrier access broadway system installation manual (96 pages)
Summary of Contents for Carrier Access Wide Bank 28 DS3
Page 1
Wide Bank 28 DS3 UICK TART UIDE Product Number: 002-0139-0500 Product Release: 2.4 July 2004...
Page 2
– any part of this manual or software supplied with the Wide Bank 28 for any purpose other than the purchaser’s personal use without the express written permission of Carrier Access Corporation.
UICK TART UIDE Quick Start Guide In this Guide Overview Physical Installation Electrical Connections and Cabling Provision Services Maintenance Commands LED Status Indicators Fault Isolation...
Overview Overview This Wide Bank® 28 DS3 Quick Start Guide is intended for experienced installers and users who do not need the detailed installation and setup instructions provided in the User Manual. For detailed information and instructions, refer to the following chapters in the User Manual, included on the CD-ROM disk in the shipping box.
Electrical Connections and Cabling Electrical Connections and Cabling For detailed information, refer to Chapter 5 in the Wide Bank 28 DS3 User Manual. 1. Power Connection. ALWAYS Connect BOTH –48VDC Connectors, and connect the ground lugs to the building ground.
RS-232 port must be used to set up the Ethernet and TL1 ports for remote management.) For detailed information, refer to Chapter 6 in the Wide Bank 28 DS3 User Manual. CLI Tips and Tricks The following tips and tricks can be helpful when using the Command Line...
Quick Start Provision Services Starting CLI Session 1. Connect PC to Craft RS-232 Port on Wide Bank 28 DS3 connector panel. 2. Set PC terminal interface for: 9600 baud, 8 data bits, no parity bit, one stop bit, no flow control.
Set DS3 Frame ID. ds3 gennumber "number" Set DS3 Generator Number. ds3 locationid "identifier" Set DS3 Location ID. ds3 portnumber "number" Set DS3 Port Number. ds3 unit "unit" Set DS3 Unit ID. Wide Bank 28 DS3 - Release 2.4 July 2004...
Page 10
"Wide Bank 28 M13 Multiplexer" SNMP values are defaults. snmp location "Wide Bank 28 Location" snmp contact "Wide Bank 28 Contact" snmp getcomm "public" snmp setcomm "public" snmp trapcomm "public" July 2004 Wide Bank 28 DS3 - Release 2.4...
Page 11
Note: Time and Date are reset when unit is powered up. CLEAR STATISTICS AND LOGS: clear {all|ds1 [n|range|all] n = 1-28, range = n-n (as in 5-8). |ds3|log [standby]|wtr} wtr clears 5 minute wait-to-restore period. Wide Bank 28 DS3 - Release 2.4 July 2004...
Maintenance Commands For a quick list of all CLI commands, use the help command. For more information on a specific command, type the command followed by help. See Chapter 8 of Wide Bank 28 DS3 User Manual for detailed information.
Page 13
Send a Code toward low-speed drop test Perform selected self-test(s) ping ipaddr [n] [d] Send IP Ping to ipaddr up to n times with d milliseconds delay between pings results Display Results of Last Test(s) Wide Bank 28 DS3 - Release 2.4 July 2004...
LED Status Indicators LED Status Indicators Status LED indicators on the Wide Bank 28 DS3 Control Panel provide a visual means of identifying system status, high-speed DS3 line condition, low-speed DS1/E1 line status, and Ethernet link status. (See next page for LED meanings.) For more information about Wide Bank 28 DS3 alarms and reporting, see Chapter 7 of Wide Bank 28 DS3 User Manual.
Page 15
Low or Missing, or -48V Internal Power Failed Normal Operation GREEN ETHERNET STATUS 5V Onboard Power (On Rear Panel) Supply Failed LED State Meaning No Power or No Link GREEN Link OK Wide Bank 28 DS3 - Release 2.4 July 2004...