Carrier Access Wide Bank 28 DS3 User Manual page 232

Hide thumbs Also See for Wide Bank 28 DS3:
Table of Contents

Advertisement

CLI Commands and Messages
CLI Command List
Message:
Equipment
---------
DS3 Controller A
DS3 Controller B
DS1 Card 1
DS1 Card 2
DS1 Card 3
DS1 Card 4
DS1 Card 5
DS1 Card 6
DS1 Card 7
DS1 Spare Card
Equipment
DS3 Controller A/B
DS1/E1 Card
8-44
Status
------
Active
Card not present
Active
Active
Active
Active
Active
Active
Active
Active
Status
Description
Active
Controller card is installed and in active mode (DS3 circuit is active)
Standby
Controller is installed and in standby mode
Not Present
Controller is not installed
Not Ready
Controller is present but is not communicating with the active card
for unknown reasons
Fail
Controller hardware failure
Active
DS1/E1 card is installed and active but individual DS1/E1 circuits
may have failed and be on Spare card
Not Present
DS1/E1 card is not installed
MSO Active
DS1/E1 MSO card (relay and electronics) is installed and active but
individual DS1/E1 circuits may have failed and be on Spare card
MSO Relay Only
DS1/E1 MSO relay card is installed but electronics card is missing.
Active on Spare
Circuits have been switched to Spare card.
MSO Relay Only
DS1/E1 MSO relay card is installed but electronics card is missing.
Not Active
Circuits have been switched to Spare card.
MSO Relay Only
DS1/E1 MSO relay card is installed but electronics card is missing.
Conflict On Spare
Multiple MSO card removals prevent switching circuits to Spare.
MSO Relay Only
DS1/E1 MSO relay card is installed but electronics card is missing.
Spare Not Present
Circuits cannot be switched because Spare card is not installed.
Wrong Card for
System mode is set to DS1 when E1 card is installed, or vice versa.
Mode
Status applies to both MSO and non-MSO card types.
July 2004
Wide Bank 28 DS3 - Release 2.4