Carrier Access Wide Bank 28 DS3 User Manual page 200

Hide thumbs Also See for Wide Bank 28 DS3:
Table of Contents

Advertisement

CLI Commands and Messages
CLI Command List
Security:
Syntax:
Example:
Example:
Example:
8-12
Set - rw and above
Show - ro and above
alarms standby {ds3_selftest|othercontrollerbad}
{critical|major|minor|na|nr}
Field
ds3_selftest
othercontrollerbad
critical
major
minor
na
nr
alarms standby ds3_selftest
Set to Not Reported
Indicates that standby Controller self-test failure alarm severity is currently set to Not
Reported (nr).
alarms standby ds3_selftest minor
Set to Minor
Sets standby Controller self-test failure alarm severity to Minor.
alarms standby ds3_selftest major
Notice: Limited to Minor by Active Setting
Set to Major
Sets standby Controller self-test failure alarm severity to Major. However, the
accompanying "Notice" indicates that this alarm severity will be limited to Minor
because the active Controller alarm severity is currently set to Minor. The standby
Controller alarm severity can be no higher than the active Controller setting.
Description
Standby DS3 Controller failed Self-Test
Active DS3 Controller lost communications with the
standby Controller
Set alarm condition level to Critical
Set alarm condition level to Major
Set alarm condition level to Minor
Not Alarmed. Condition is logged and reported as an
event (REPT EVT) instead of an alarm (REPT ALM).
Not Reported. Condition is logged but not reported.
July 2004
Wide Bank 28 DS3 - Release 2.4

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Carrier Access Wide Bank 28 DS3