PN 88300150
S30
Inactivity Timer
Unit: 1 min.
Range: 0-255
Default: 0
Description: S30 causes the modem to disconnect if no data is transmitted or received for a specified
time. This timer runs during both Reliable and Normal connections. The timer restarts any
time a data character is passed through the serial port (either sent or received). If noise on
the phone line causes an error to be received during Normal mode, this also restarts the
timer. The inactivity timer is disabled by setting S30 to 0, which is the factory default
setting.
S32
Time Elapse for Escape Sequence
Unit: 100 mSec.
Range: 0-255
Default: 20
Description: S32 sets the time period to validate the escape sequence. If the time interval expires before
the escape sequence is employed (by hitting ENTER), the escape sequence is aborted.
The default is 20 units (one second).
S34
Buffer Length of Command Mode after On-line Escape Sequence
Unit: ASCII
Range: 0-60
Default: 10
Description: If the number of characters after AT exceeds the S34 buffer length value, the buffer is
cleared and the escape sequence is aborted.
S36
DTR Busy-out Time Length
Unit: 1 sec.
Range: 0-255 sec.
Default: 0 sec.
Description: S36 sets the amount of time (in seconds) that the
modem waits when DTR goes off, before going off hook (busy).
S37
DTR Busy-in Time Length
Unit: 1 sec.
Range: 0-255 sec.
Default: 5 sec.
Description: S37 sets the amount of time (in seconds) that the
modem waits when DTR comes back on, before going on hook.