Line Feed Character
Unit: ASCII
Range: 0-127
Default: 10
Description: S4 defines the character recognized as Line Feed. The default setting is CTRL-J (Decimal
10), which is the ASCII code for the Line Feed key on most keyboards. S4 may be set for
any ASCII character.
S5
Backspace Character
Unit: ASCII
Range: 0-127
Default: 8
Description: S5 defines the character recognized as BACKSPACE. The default setting is CTRL-H
(Decimal 8), which is the BACKSPACE key on most keyboards. S5 may be set for any
ASCII character.
S6
Wait Time for Dial Tone
Unit: 1 sec.
Range: 2-255, 4-7*
Default: 2, 4*
Description: S6 sets the amount of time the modem waits after the ENTER key is pressed and a dial
tone is detected before executing a dial command. The default setting is two seconds
(Decimal 2) or four* seconds.
S7
Time for Carrier (Abort Timer)
Unit: 1 sec.
Range: 1-255, 1-45*
Default: 45
Description: S7 defines the Abort Timer (lack of carrier) delay time. The default value is 45 seconds
(Decimal 45). This means that, after dialing, the modem waits for a carrier signal for up to
45 seconds and, if none is detected, aborts the call. The maximum S7 value is 255 (or 45*)
seconds.
S8
Pause Time for Comma
Unit: 1 sec.
Range: 0-255, 4-7*
Default: 2, 4*
Description: S8 sets the length of the pause caused by a comma inserted in a dialing command. The
default setting is two seconds (Decimal 2) or four* seconds, where each unit is one second.
S8 may be set for up to 255 seconds.
S8 also sets the time the modem waits before retrying a call after detecting a busy signal.
Some computer systems need more than two seconds to reset (in which case you should
increase the value of S8).