PN 88300150
S9
Carrier Detect Response Time
Unit: 100 mSec.
Range: 1-255
Default: 6
Description: S9 sets the time delay between when the modem first detects a valid incoming carrier
signal and when the modem turns on its Carrier Detect circuit. The default setting is 600
milliseconds, or six units of 100 mSec each (Decimal 6). S9 may be set for up to 25.5
seconds.
S10
Carrier Loss Disconnect Delay Time
Unit: 100 mSec.
Range: 0-255
Default: 7
Description: S10 sets the time a carrier signal must be lost before the modem disconnects. S10 can
only be set at speeds of 2400 bps or less. The default setting is 700 mSec, or seven units
(Decimal 7) of 100 mSec. Maximum delay is 25.4 seconds (Decimal 254). Setting the S10
value to 255 causes the modem to not disconnect with loss of carrier.
S11
Tone Dialing: Tone Spacing and Duration
Unit: 1 mSec.
Range: 1-255, 80-255*
Default: 70, 80*
Description: S11 sets the speed of tone dialing (spacing and tone duration times). The default value is
70 units (Decimal 70) or 80* units, where each unit is one mSec, meaning that each tone is
on for 70 mSec with a 70 mSec pause between each.
The minimum S11 value allowed by most telephone systems is 50 mSec (50 units). Very
few telephone systems can handle anything faster than that. The maximum S11 value is
255 mSec (255 units).
S13
Remote Configuration Escape Character
Unit: ASCII
Range: 0-127
Default: 37 (% sign)
Description: S13 defines the remote configuration escape character (which becomes your modem's
remote configuration character). The default is three percent symbols (%%%). When the
S13 character is entered three consecutive times from a remotely connected site, your
modem responds with its Remote Configuration procedure.
S17
Changing Break Time
Unit: 10 mSec.
Range: 0-2500 mSec
Default: 250 mSec.
Description: S17 defines the break time (space) to the PC. Break duration is adjustable. The break time
is changed in 10 mSec increments by increasing or decreasing the value of S17.
4/3/01
41