Measured Value Output

For technical information on the RS-232-C/V.24
data interface (X31), information on the data
format, etc., see the chapter "RS-232-C/V.24 Data
Interface (X31)."
Measured values can be transmitted over the RS-232-C/V.24
interface (X31), for example to a printer or PC.
There are several ways to start measured value output:
ä
In the linear measurement mode:
Press MOD repeatedly until the PRINT indicator starts
blinking, then start measured value output with ENT.
In the angular measurement mode:
Press the MOD key (this feature can be disabled with
operating parameter 86).
or
ä
Input the command STX (Ctrl B) over the RXD input of the
RS-232-C/V.24 interface (X31);
or
ä
Input a signal for measured data output (Pulse or Contact)
at the D-sub connection EXT (X41).
14